Magnesium in Presence of Calcium: Selective Precipitation
Separate Mg²⁺ from Ca²⁺: precipitate Ca as oxalate, confirm Mg in the filtrate.
Theoretical Foundations
In ammoniacal medium, (NH₄)₂C₂O₄ precipitates CaC₂O₄ (Ksp ~10⁻⁹) quantitatively while MgC₂O₄ (Ksp ~10⁻⁵) stays dissolved. The filtrate is then tested for Mg²⁺ with (NH₄)₂HPO₄ (white crystalline MgNH₄PO₄) or titan yellow — a standard Group V/VI boundary separation.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Filter paper + funnel
- Dropper
- Test-tube rack
Chemical Reagents
- Ca²⁺ + Mg²⁺ mixture
- Ammonium oxalate solution
- Aqueous NH₃
- Diammonium hydrogen phosphate
- NH₄Cl
Step-by-Step Practical Procedure
- Make the mixture ammoniacal; add ammonium oxalate: white CaC₂O₄.
- Filter; confirm the residue is Ca (dissolves in HCl, brick-red flame).
- To the filtrate add NH₄Cl + NH₃ + (NH₄)₂HPO₄: white crystalline MgNH₄PO₄.
- Titan-yellow cross-check on the filtrate: red = Mg confirmed.
Observations & Expected Results
White oxalate (Ca); white crystalline phosphate + red lake (Mg) from filtrate.
Worked Stoichiometric Calculations
Problem: MgC₂O₄ Ksp ~8.6×10⁻⁵. With [C₂O₄²⁻] = 0.01 M, what [Mg²⁺] stays dissolved?
Working: [Mg²⁺] up to 8.6×10⁻³ M stays dissolved — test concentrations remain in solution while Ca²⁺ precipitates fully.
Safety Precautions & Hazard Control
- Oxalate toxicity — gloves.
- Ammonia fumes.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Calcium/magnesium residues to chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: Why doesn't MgC₂O₄ precipitate here?
A: Its Ksp is ~10⁴ times larger than CaC₂O₄'s — the oxalate concentration is tuned to the calcium window.
Q: What if both precipitate?
A: Oxalate was too concentrated or the medium not ammoniacal — repeat with dilute reagent.