CHEMVEN

Confirmatory Test for Manganese: Oxidation to Permanganate

Confirm Mn²⁺ by oxidation to purple MnO₄⁻ with PbO₂, NaBiO₃ or persulphate/Ag⁺.

Level: UniversitySafety: Needs supervisionTime: 40 min
Aim of Experiment: Confirm Mn²⁺ by oxidation to purple MnO₄⁻ with PbO₂, NaBiO₃ or persulphate/Ag⁺.

Theoretical Foundations

Strong oxidants convert Mn²⁺ to MnO₄⁻ in acid: 2Mn²⁺ + 5PbO₂ + 4H⁺ → 2MnO₄⁻ + 5Pb²⁺ + 2H₂O. The intense purple colour is unmistakable and very sensitive. Sodium bismuthate (NaBiO₃) is the classical solid oxidant; persulphate with Ag⁺ catalyst is the modern alternative.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Water bath
  • Filter paper
  • Test-tube rack

Chemical Reagents

  • Manganese(II) sulphate (~0.1 M)
  • Sodium bismuthate (solid) or PbO₂
  • Dilute HNO₃ (~2 M)
  • Dilute H₂SO₄

Step-by-Step Practical Procedure

  1. Acidify Mn²⁺ solution with dilute HNO₃.
  2. Add a pinch of NaBiO₃ (or PbO₂) and warm; filter off excess oxidant.
  3. Intense purple filtrate = MnO₄⁻ = Mn²⁺ confirmed.
  4. Compare with a blank (no manganese) — stays colourless.

Observations & Expected Results

Colourless → intense purple on oxidation.

Worked Stoichiometric Calculations

Problem: Balance: Mn²⁺ + BiO₃⁻ + H⁺ → MnO₄⁻ + Bi³⁺ + H₂O (acidic).

Working: 2Mn²⁺ + 5BiO₃⁻ + 14H⁺ → 2MnO₄⁻ + 5Bi³⁺ + 7H₂O.

Safety Precautions & Hazard Control

  • NaBiO₃/PbO₂ are strong oxidants — keep from organics.
  • Lead waste if PbO₂ used.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Manganese/lead/bismuth residues to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why filter before judging the colour?

A: Excess solid oxidant (brown PbO₂) would mask the purple.

Q: Why HNO₃ and not HCl for acidification?

A: HCl would be oxidised to Cl₂ by these strong oxidants, consuming reagent and giving false chemistry.