Separation of Fe³⁺, Al³⁺ and Cr³⁺ by Peroxide Oxidation
Resolve the Group III hydroxide mixture: Fe stays precipitated while Al and Cr dissolve, then split Al from Cr.
Theoretical Foundations
Boiling the Group III hydroxides with NaOH + H₂O₂: Fe(OH)₃ stays insoluble; Al(OH)₃ dissolves as [Al(OH)₄]⁻; Cr(OH)₃ is oxidised to soluble yellow CrO₄²⁻. Filtering isolates Fe³⁺. Boiling the filtrate destroys excess H₂O₂, then NH₄Cl reprecipitates Al(OH)₃ (white) while chromate stays yellow in solution.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Water bath
- Filter paper + funnel
- Test-tube rack
Chemical Reagents
- Mixed Group III hydroxides
- Sodium hydroxide (~2 M)
- Hydrogen peroxide (3%)
- Solid NH₄Cl
Step-by-Step Practical Procedure
- Boil the mixed hydroxides with NaOH + H₂O₂ for 3–4 min; filter.
- Brown residue = Fe(OH)₃ → confirm Fe³⁺ (thiocyanate).
- Boil the yellow filtrate to destroy excess H₂O₂.
- Add solid NH₄Cl and warm: white gelatinous Al(OH)₃ precipitates.
- The remaining yellow filtrate = CrO₄²⁻ → acidify to orange for chromium.
Observations & Expected Results
Brown residue (Fe); white precipitate on NH₄Cl (Al); yellow→orange filtrate (Cr).
Worked Stoichiometric Calculations
Problem: Why boil before adding NH₄Cl?
Working: Residual H₂O₂ would oxidise/reduce inconsistently and give O₂ bubbles that disrupt precipitation; boiling decomposes it.
Safety Precautions & Hazard Control
- Hot NaOH/H₂O₂ — corrosive, wear goggles.
- Chromate waste segregated.
- Wear safety goggles and a lab coat throughout the experiment.
Waste Disposal Protocol
Iron/aluminium residues to heavy-metal waste; chromate filtrate to Cr(VI) waste.
Viva Voce Oral Defense Questions & Answers
Q: Why does NH₄Cl reprecipitate Al(OH)₃?
A: NH₄⁺ + [Al(OH)₄]⁻ → Al(OH)₃ + NH₃ + H₂O — ammonium ion destroys the aluminate complex.
Q: Could Na₂O₂ replace H₂O₂?
A: Yes — sodium peroxide in NaOH is the classical reagent for this oxidation.