CHEMVEN

Separation of Fe³⁺, Al³⁺ and Cr³⁺ by Peroxide Oxidation

Resolve the Group III hydroxide mixture: Fe stays precipitated while Al and Cr dissolve, then split Al from Cr.

Level: UniversitySafety: Needs supervisionTime: 50 min
Aim of Experiment: Resolve the Group III hydroxide mixture: Fe stays precipitated while Al and Cr dissolve, then split Al from Cr.

Theoretical Foundations

Boiling the Group III hydroxides with NaOH + H₂O₂: Fe(OH)₃ stays insoluble; Al(OH)₃ dissolves as [Al(OH)₄]⁻; Cr(OH)₃ is oxidised to soluble yellow CrO₄²⁻. Filtering isolates Fe³⁺. Boiling the filtrate destroys excess H₂O₂, then NH₄Cl reprecipitates Al(OH)₃ (white) while chromate stays yellow in solution.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Water bath
  • Filter paper + funnel
  • Test-tube rack

Chemical Reagents

  • Mixed Group III hydroxides
  • Sodium hydroxide (~2 M)
  • Hydrogen peroxide (3%)
  • Solid NH₄Cl

Step-by-Step Practical Procedure

  1. Boil the mixed hydroxides with NaOH + H₂O₂ for 3–4 min; filter.
  2. Brown residue = Fe(OH)₃ → confirm Fe³⁺ (thiocyanate).
  3. Boil the yellow filtrate to destroy excess H₂O₂.
  4. Add solid NH₄Cl and warm: white gelatinous Al(OH)₃ precipitates.
  5. The remaining yellow filtrate = CrO₄²⁻ → acidify to orange for chromium.

Observations & Expected Results

Brown residue (Fe); white precipitate on NH₄Cl (Al); yellow→orange filtrate (Cr).

Worked Stoichiometric Calculations

Problem: Why boil before adding NH₄Cl?

Working: Residual H₂O₂ would oxidise/reduce inconsistently and give O₂ bubbles that disrupt precipitation; boiling decomposes it.

Safety Precautions & Hazard Control

  • Hot NaOH/H₂O₂ — corrosive, wear goggles.
  • Chromate waste segregated.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Iron/aluminium residues to heavy-metal waste; chromate filtrate to Cr(VI) waste.

Viva Voce Oral Defense Questions & Answers

Q: Why does NH₄Cl reprecipitate Al(OH)₃?

A: NH₄⁺ + [Al(OH)₄]⁻ → Al(OH)₃ + NH₃ + H₂O — ammonium ion destroys the aluminate complex.

Q: Could Na₂O₂ replace H₂O₂?

A: Yes — sodium peroxide in NaOH is the classical reagent for this oxidation.

← Back to Experiments Directory