CHEMVEN

Confirmatory Test for Mercury(II): Stannous Chloride Reduction

Confirm Hg²⁺ by stepwise reduction with SnCl₂: white Hg₂Cl₂ then grey Hg.

Level: UniversitySafety: Advanced lab onlyTime: 30 min
Aim of Experiment: Confirm Hg²⁺ by stepwise reduction with SnCl₂: white Hg₂Cl₂ then grey Hg.

Theoretical Foundations

SnCl₂ reduces Hg²⁺ first to white Hg₂Cl₂: 2HgCl₂ + SnCl₂ → Hg₂Cl₂ + SnCl₄; excess SnCl₂ reduces further to grey metallic mercury: Hg₂Cl₂ + SnCl₂ → 2Hg + SnCl₄. The white→grey sequence is characteristic of Hg(II).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Test tubes
  • Dropper
  • Fume cupboard
  • Test-tube rack

Chemical Reagents

  • Mercury(II) chloride (~0.05 M)
  • Stannous chloride (freshly prepared)
  • Dilute HCl

Step-by-Step Practical Procedure

  1. Add a few drops of SnCl₂ to HgCl₂ solution: white precipitate of Hg₂Cl₂.
  2. Add excess SnCl₂: the white precipitate turns grey (metallic Hg).
  3. Note the colour sequence carefully — it is the confirmatory observation.
  4. Run a reagent blank without Hg²⁺ to confirm the reagents give no precipitate.

Observations & Expected Results

White silky precipitate → grey metallic deposit with excess reductant.

Worked Stoichiometric Calculations

Problem: In the first step, what is the mole ratio HgCl₂ : SnCl₂?

Working: 2:1 — 2HgCl₂ + SnCl₂ → Hg₂Cl₂ + SnCl₄.

Safety Precautions & Hazard Control

  • Mercury(II) chloride is very toxic — fume cupboard, gloves.
  • Fresh SnCl₂ only.
  • Wear safety goggles and a lab coat throughout the experiment.

Waste Disposal Protocol

Mercury waste to the dedicated mercury container.

Viva Voce Oral Defense Questions & Answers

Q: Why must SnCl₂ be fresh?

A: Air oxidises Sn²⁺ to Sn⁴⁺, which cannot reduce Hg²⁺.

Q: How does this differ from the Hg(I) ammonia test?

A: That test blackens via disproportionation; this one reduces stepwise white→grey, specific to Hg(II) salts.