Lead-Acid Cell: A Rechargeable 2 V System
To build a small lead-acid cell, measure its ~2.0 V EMF, and demonstrate rechargeability.
Theoretical Foundations
Discharge: Pb + PbO2 + 2H2SO4 → 2PbSO4 + 2H2O (E° ≈ 2.04 V per cell; six cells give a 12 V battery). Charging reverses it. Both electrodes become PbSO4 on discharge — the acid is consumed, so specific gravity tracks charge state. Lead and sulfuric acid demand advanced-lab handling.
Required Apparatus & Chemicals
Laboratory Apparatus
- Small beaker
- Lead strips (2)
- DC supply for charging
- Voltmeter
- Hydrometer (optional)
- Gloves, goggles, apron
Chemical Reagents
- Sulfuric acid, about 2 M (about 100 mL)
- Lead strips (2, about 10 g each)
- Sodium bicarbonate (for neutralizing spills)
Step-by-Step Practical Procedure
- Wearing full PPE, place two lead strips in 2 M H2SO4 (do not let them touch).
- Measure the initial voltage (low, unformed plates).
- Charge at low current (0.2 A) for 20 minutes: one plate darkens (PbO2).
- Measure the EMF — now about 2.0 V.
- Discharge through a small bulb and watch the voltage fall.
- Recharge and confirm the voltage recovers.
Observations & Expected Results
After forming, the cell gives ~2.0 V, lights the bulb, and recovers on recharge — a true secondary cell in miniature.
Worked Stoichiometric Calculations
Problem: A 12 V car battery contains 6 cells. What is the voltage per cell, and how many moles of H2SO4 are consumed per mole of Pb discharged?
Working: 12/6 = 2.0 V per cell. From the equation: 2 mol H2SO4 per mol Pb.
Safety Precautions & Hazard Control
- Sulfuric acid is severely corrosive; full PPE and a fume hood.
- Lead is toxic; wear gloves, wash hands.
- Charging releases hydrogen — no flames, ventilate.
- Neutralize spills with sodium bicarbonate.
Waste Disposal Protocol
Acid must be neutralized and lead collected as hazardous waste — never down the drain.
Viva Voce Oral Defense Questions & Answers
Q: Write the overall cell reaction.
A: Pb + PbO2 + 2H2SO4 ⇌ 2PbSO4 + 2H2O (discharge →, charge ←).
Q: How can you tell the state of charge?
A: Acid specific gravity falls on discharge as H2SO4 is consumed.
Q: Why must both plates be lead compounds?
A: Both electrodes convert to PbSO4 on discharge; charging regenerates Pb and PbO2.