Chloropentaamminerhodium(III) Chloride: [Rh(NH₃)₅Cl]Cl₂ and 4d Inertness
To prepare [Rh(NH₃)₅Cl]Cl₂ and compare 4d vs 3d inertness.
Theoretical Foundations
Rh(III) (4d⁶, low-spin) is even more substitution-inert than Co(III) — 4d orbitals give larger Δ₀. [Rh(NH₃)₅Cl]Cl₂ is made by prolonged heating of RhCl₃ with ammonia. Its aquation is ~10⁶ times slower than the cobalt analogue, vividly showing the 3d/4d inertness trend.
Required Apparatus & Chemicals
Laboratory Apparatus
- 250 mL beaker
- Glass rod
- Buchner funnel
- Filter flask
- Weighing balance
- Hot plate
- Fume hood
Chemical Reagents
- Rhodium(III) chloride hydrate (~1 g)
- Concentrated ammonia (~30 mL)
- Ammonium chloride (~1 g)
- Ethanol
- Distilled water
Step-by-Step Practical Procedure
- Dissolve 1 g RhCl₃·xH₂O in 15 mL water; add 30 mL conc. NH₃ + 1 g NH₄Cl.
- Heat at 80 °C for 2 h with stirring — yellow solution of [Rh(NH₃)₅Cl]²⁺ forms slowly.
- Cool; add ethanol — pale-yellow crystals separate.
- Filter, wash with ethanol, dry.
- Test inertness: boil a sample with AgNO₃ — no immediate AgCl (coordinated Cl⁻ inert); compare with instant precipitation for NaCl.
Observations & Expected Results
Pale-yellow crystals; even boiling with AgNO₃ gives AgCl only very slowly — extreme inertness of 4d⁶ Rh(III) vs 3d Co(III).
Worked Stoichiometric Calculations
Problem: Calculate the EAN of Rh in [Rh(NH₃)₅Cl]Cl₂.
Working: Rh atomic number 45. Rh(III): 45 − 3 = 42; 5 NH₃ + Cl⁻ donate 12 → 54 = Xe.
Safety Precautions & Hazard Control
- Rhodium is precious — microscale, collect all waste.
- Ammonia — fume hood.
- Long heating — do not boil dry.
Waste Disposal Protocol
All rhodium waste to the precious-metal container.
Viva Voce Oral Defense Questions & Answers
Q: Why is Rh(III) more inert than Co(III)?
A: 4d orbitals → larger Δ₀ → higher activation barrier for substitution.
Q: What is the trend down a group?
A: Inertness increases 3d < 4d < 5d for the same d-count.
Q: What colour and why?
A: Pale yellow — d–d bands of low-spin d⁶ shifted to higher energy (large Δ₀).