CHEMVEN

Ligand Field Stabilisation Energy: Comparing Hydration Enthalpies Across d⁵–d¹⁰

To extract LFSE from hydration enthalpy trends of M²⁺ ions (data analysis).

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To extract LFSE from hydration enthalpy trends of M²⁺ ions (data analysis).

Theoretical Foundations

Hydration enthalpies of [M(H₂O)₆]²⁺ show a double-humped curve vs atomic number; the humps are LFSE (maxima at d³ and d⁸). Subtracting the smooth ionic trend (Ca²⁺, Mn²⁺, Zn²⁺ — d⁰, d⁵, d¹⁰, LFSE = 0) leaves the LFSE contribution, e.g. ~ −270 kJ/mol for Ni²⁺ (d⁸).

Required Apparatus & Chemicals

Laboratory Apparatus

  • Computer / spreadsheet
  • Graph paper
  • Calculator
  • Literature data table (provided)

Chemical Reagents

  • None — data-analysis experiment
  • Hydration enthalpy data table (provided)
  • LFSE worksheet (provided)

Step-by-Step Practical Procedure

  1. Tabulate ΔH_hyd for M²⁺ (Ca to Zn) from the provided data.
  2. Plot ΔH_hyd vs atomic number — note the double hump.
  3. Draw the smooth baseline through Ca²⁺ (d⁰), Mn²⁺ (d⁵), Zn²⁺ (d¹⁰).
  4. Measure deviations from baseline = LFSE for each ion.
  5. Compare experimental LFSE with theoretical (−0.4x + 0.6y)Δ₀ values.

Observations & Expected Results

Double-humped curve; deviations peak at V²⁺ (d³) and Ni²⁺ (d⁸), zero at Mn²⁺ (d⁵) — matching LFSE predictions.

Worked Stoichiometric Calculations

Problem: Ni²⁺ deviates by −270 kJ/mol from baseline. If Δ₀ = 8500 cm⁻¹, compare with theory.

Working: Theory: −1.2Δ₀ = −1.2 × 8500 cm⁻¹ = −10,200 cm⁻¹ = −122 kJ/mol... (units: 1 cm⁻¹ = 0.01196 kJ/mol → −122 kJ/mol). Observed −270 kJ/mol includes additional covalent/ionic terms; order of magnitude agrees.

Safety Precautions & Hazard Control

  • Use the provided verified data table.
  • Check unit conversions (cm⁻¹ to kJ/mol).
  • No chemicals — no lab hazards.

Waste Disposal Protocol

No chemical waste generated.

Viva Voce Oral Defense Questions & Answers

Q: Why double-humped?

A: LFSE is zero at d⁰, d⁵, d¹⁰ and maximal at d³, d⁸.

Q: Why is Mn²⁺ on the baseline?

A: High-spin d⁵: CFSE = 3(−0.4) + 2(0.6) = 0.

Q: What causes the baseline trend?

A: Decreasing ionic radius across the period increases hydration enthalpy smoothly.

← Back to Experiments Directory