CHEMVEN

Preparation of Dicyanoargentate(I): K[Ag(CN)₂] (Silver Plating Salt)

To prepare K[Ag(CN)₂], the classic silver electroplating salt.

Level: UniversitySafety: Advanced lab onlyTime: 60 min
Aim of Experiment: To prepare K[Ag(CN)₂], the classic silver electroplating salt.

Theoretical Foundations

AgCN dissolves in KCN: AgCN + CN⁻ → [Ag(CN)₂]⁻ (linear, d¹⁰). The complex lowers free Ag⁺ to ~10⁻²¹ M, giving smooth, adherent electroplated silver — the basis of silver plating baths. Formation constant β₂ ≈ 10²¹.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 250 mL beaker
  • Glass rod
  • Buchner funnel
  • Filter flask
  • Weighing balance
  • Fume hood
  • Electroplating cell (optional)

Chemical Reagents

  • Silver nitrate (~3.4 g)
  • Potassium cyanide (~3 g, CAUTION — teacher dispenses)
  • Sodium carbonate
  • Distilled water

Step-by-Step Practical Procedure

  1. Precipitate AgCN: add KCN solution to AgNO₃ until precipitation is complete.
  2. Add excess KCN with stirring — precipitate redissolves as K[Ag(CN)₂].
  3. Filter, concentrate the filtrate, cool — colourless crystals of K[Ag(CN)₂] separate.
  4. Filter, dry in a desiccator.
  5. Optional: electroplate a copper coin from the solution at low current — bright silver deposit.

Observations & Expected Results

White AgCN dissolves in excess cyanide; colourless crystals of K[Ag(CN)₂] form; electroplating gives a bright adherent silver layer.

Worked Stoichiometric Calculations

Problem: β₂ = 1×10²¹. In 0.1 M [Ag(CN)₂]⁻ with 0.1 M excess CN⁻, find free [Ag⁺].

Working: [Ag⁺] = [complex]/(β₂[CN⁻]²) = 0.1/(10²¹ × 0.01) = 1×10⁻²⁰ M.

Safety Precautions & Hazard Control

  • KCN is lethal — teacher only, fume hood, gloves, never with acids.
  • All cyanide waste to the cyanide bottle.
  • Electroplating — low voltage only.

Waste Disposal Protocol

Every cyanide-containing drop to the labelled cyanide waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is the complex used for plating?

A: Very low free Ag⁺ gives slow, uniform deposition — smooth adherent plate.

Q: What is the geometry?

A: Linear [Ag(CN)₂]⁻.

Q: What is the EAN of Ag?

A: 47 − 1 + 4 = 50.

← Back to Experiments Directory