Ligand Exchange Kinetics: [Fe(phen)₃]²⁺ Formation Rate
To measure the rate of formation of [Fe(phen)₃]²⁺ spectrophotometrically.
Theoretical Foundations
Fe²⁺ + 3phen → [Fe(phen)₃]²⁺ is fast but measurable by stopped-flow or by conventional mixing with excess phen (pseudo-first-order). The deep-red MLCT band at 510 nm (ε ≈ 11,000) is monitored. Under pseudo-first-order conditions, ln(A∞ − At) vs t gives kobs; varying [phen] gives the rate law.
Required Apparatus & Chemicals
Laboratory Apparatus
- UV-Vis spectrophotometer
- Cuvettes
- Stopwatch
- Volumetric flasks
- Pipettes
- Weighing balance
Chemical Reagents
- Iron(II) ammonium sulphate (Mohr's salt, ~0.4 g)
- 1,10-phenanthroline (~1 g)
- Acetate buffer pH 4
- Distilled water
Step-by-Step Practical Procedure
- Prepare 1×10⁻⁴ M Fe²⁺ (Mohr's salt) in acetate buffer.
- Prepare phen solutions of 5×10⁻⁴, 1×10⁻³, 2×10⁻³ M.
- Mix Fe²⁺ with excess phen in a cuvette; start stopwatch; record A₅₁₀ every 15 s for 5 min.
- Plot ln(A∞ − At) vs t → kobs for each [phen].
- Plot kobs vs [phen] to find the order in phen.
Observations & Expected Results
Red colour develops over ~2–3 min; first-order plots linear; kobs proportional to [phen] — first order in phen under these conditions.
Worked Stoichiometric Calculations
Problem: kobs = 0.020 s⁻¹ at [phen] = 1.0×10⁻³ M (first order in phen). Find the second-order rate constant.
Working: k = kobs/[phen] = 0.020/1.0×10⁻³ = 20 M⁻¹s⁻¹.
Safety Precautions & Hazard Control
- Mohr's salt solutions oxidise — prepare fresh.
- Phenanthroline — gloves.
- Buffer pH 4 keeps Fe²⁺ stable.
Waste Disposal Protocol
Iron–phenanthroline waste to heavy-metal waste.
Viva Voce Oral Defense Questions & Answers
Q: Why pseudo-first-order?
A: Large excess of phen makes its concentration effectively constant.
Q: Why monitor 510 nm?
A: Intense MLCT band of [Fe(phen)₃]²⁺ (ε ≈ 11,000).
Q: What does the rate law tell us?
A: The mechanism's composition of the rate-determining step.