CHEMVEN

Determination of Chloride in [Co(NH₃)₅Cl]Cl₂ by Conductometry

To find the number of ions from molar conductivity and assign the complex's formula.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To find the number of ions from molar conductivity and assign the complex's formula.

Theoretical Foundations

Molar conductivity (Λm) indicates the number of ions: ~120–160 S·cm²/mol for 1:1, ~230–270 for 1:2, ~400–450 for 1:3 electrolytes (in water). [Co(NH₃)₅Cl]Cl₂ is a 1:2 electrolyte (Λm ≈ 250), while [Co(NH₃)₆]Cl₃ is 1:3 (Λm ≈ 430) — Werner's evidence for inner vs outer sphere chloride.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conductivity meter (calibrated)
  • Conductivity cell
  • Volumetric flasks (250 mL)
  • Pipettes
  • Weighing balance
  • Beakers
  • Thermometer

Chemical Reagents

  • [Co(NH₃)₅Cl]Cl₂ (~0.25 g)
  • [Co(NH₃)₆]Cl₃ (~0.27 g, reference)
  • KCl standard (0.01 M, for cell constant)
  • Distilled water (conductivity water)

Step-by-Step Practical Procedure

  1. Calibrate the cell with 0.01 M KCl to get the cell constant.
  2. Prepare 0.001 M solutions of each cobalt complex in conductivity water.
  3. Measure conductivity at 25 °C; compute Λm = (κ × 1000)/M.
  4. Compare with standard ranges to assign electrolyte type (1:2 vs 1:3).
  5. Conclude how many chlorides are outside the coordination sphere in each.

Observations & Expected Results

[Co(NH₃)₅Cl]Cl₂: Λm ≈ 240–260 S·cm²/mol (1:2 electrolyte, 3 ions). [Co(NH₃)₆]Cl₃: Λm ≈ 420–440 (1:3 electrolyte, 4 ions).

Worked Stoichiometric Calculations

Problem: κ = 2.50×10⁻⁴ S/cm for 0.001 M solution. Find Λm and the electrolyte type.

Working: Λm = (2.50×10⁻⁴ × 1000)/0.001 = 250 S·cm²/mol → 1:2 electrolyte (3 ions).

Safety Precautions & Hazard Control

  • Use freshly distilled conductivity water.
  • Keep temperature at 25 °C.
  • Rinse cell between samples.

Waste Disposal Protocol

Dilute cobalt solutions to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: What does 1:2 electrolyte mean?

A: One complex cation and two anions — 3 ions total per formula unit.

Q: Why must concentration be low?

A: To minimise ion pairing so Λm approaches the limiting value.

Q: How does this support Werner?

A: Ion count matches the proposed inner/outer sphere distribution of Cl⁻.

← Back to Experiments Directory