Aquation of [Co(NH₃)₅Cl]²⁺: Kinetics of Ligand Substitution
To follow the aquation [Co(NH₃)₅Cl]²⁺ + H₂O → [Co(NH₃)₅(H₂O)]³⁺ + Cl⁻ and determine its rate constant.
Theoretical Foundations
Chloropentaamminecobalt(III) undergoes slow aquation in water: the coordinated chloride is replaced by water, changing the colour from purple to pink-red. The reaction is first order in the complex. The rate can be followed by titrating the released Cl⁻ with AgNO₃ or by the colour change, plotting ln[complex] vs time.
Required Apparatus & Chemicals
Laboratory Apparatus
- 250 mL conical flask
- Burette (25 mL)
- Pipettes
- Stopwatch
- Water bath (thermostat, 25 °C)
- Test tubes
- Silver nitrate (0.02 M)
- Potassium chromate indicator
Chemical Reagents
- Chloropentaamminecobalt(III) chloride (~1 g)
- Silver nitrate solution 0.02 M (standardised)
- Potassium chromate indicator
- Distilled water
Step-by-Step Practical Procedure
- Dissolve 1.0 g [Co(NH₃)₅Cl]Cl₂ in 250 mL water at 25 °C; start the stopwatch.
- At 10-min intervals, pipette 25 mL aliquots into flasks.
- Titrate each aliquot with 0.02 M AgNO₃ using K₂CrO₄ indicator (first permanent red Ag₂CrO₄ end point).
- The titre measures total free Cl⁻ (2 initial + released); subtract the t=0 titre to get released Cl⁻.
- Plot ln(a − x) vs time; slope = −k.
Observations & Expected Results
Solution colour drifts from purple toward pink-red over ~2 h. Titre rises steadily, e.g. from 10.0 mL to ~14.5 mL, giving k ≈ 1.7×10⁻⁴ s⁻¹ at 25 °C (first-order plot linear).
Worked Stoichiometric Calculations
Problem: If k = 1.7×10⁻⁴ s⁻¹, calculate the half-life of the aquation.
Working: t½ = 0.693/k = 0.693/1.7×10⁻⁴ = 4076 s ≈ 68 min.
Safety Precautions & Hazard Control
- Keep temperature constant at 25 °C — rate is temperature sensitive.
- Silver nitrate stains; wear gloves.
- Time the aliquots accurately.
Waste Disposal Protocol
Silver-containing titration waste to the silver/heavy-metal container.
Viva Voce Oral Defense Questions & Answers
Q: What is the order of this aquation?
A: First order with respect to the complex.
Q: Why is Co(III) substitution slow?
A: Low-spin d⁶ has high crystal-field stabilisation; substitution is inert.
Q: What mechanism operates?
A: Dissociative (SN1-like) — loss of Cl⁻ is rate-determining.