Orcinol Test for RNA (Ribose)
To detect RNA via its ribose sugar using the orcinol reaction.
Theoretical Foundations
Hot HCl converts ribose to furfural, which condenses with orcinol (with FeCl3) to a green complex (660 nm). DNA gives a much weaker response, making orcinol the classic RNA test.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes
- Boiling water bath
- Test tube holder
- Pipettes
Chemical Reagents
- Orcinol reagent (orcinol + FeCl3 in HCl)
- Yeast RNA extract
- DNA solution
- Distilled water
Step-by-Step Practical Procedure
- Add 2 mL orcinol reagent to tubes with RNA extract, DNA solution and water.
- Heat in the boiling water bath for 3-5 minutes.
- Cool and observe the green colour in the RNA tube.
- Compare with the DNA tube's weak response.
- Conclude the test detects pentose of RNA.
Observations & Expected Results
The RNA tube turns green; DNA gives only a faint colour; the blank stays pale yellow.
Worked Stoichiometric Calculations
Problem: RNA standard (100 ug/mL) gives A660 = 0.60. A yeast extract gives 0.45 after 1:10 dilution. Find the extract's RNA concentration.
Working: Diluted C = 0.45/0.60 x 100 = 75 ug/mL. Extract = 75 x 10 = 750 ug/mL = 0.75 mg/mL RNA.
Safety Precautions & Hazard Control
- Orcinol reagent contains concentrated HCl; ventilate.
- Time the heating; over-heating darkens all tubes.
- FeCl3 stains; wear gloves.
- Use a holder for hot tubes.
Waste Disposal Protocol
Cool, neutralise, and drain with water; collect bulk as chemical waste.
Viva Voce Oral Defense Questions & Answers
Q: How does this differ from Bial's test (bio-mol-006)?
A: It is the same chemistry applied to nucleic acids: Bial's detects any pentose, here used specifically to reveal RNA's ribose.
Q: Why is the DNA response weak?
A: Deoxyribose dehydrates differently and yields little furfural under these conditions.