CHEMVEN

Lipid Peroxidation: TBARS Test on Heated Oil

To measure secondary oxidation in repeatedly heated oil using the thiobarbituric acid reactive substances (TBARS) test.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To measure secondary oxidation in repeatedly heated oil using the thiobarbituric acid reactive substances (TBARS) test.

Theoretical Foundations

Malondialdehyde (MDA), a secondary lipid oxidation product, condenses with thiobarbituric acid to a pink complex (532 nm). Repeated frying raises TBARS; results are expressed as mg MDA per kg oil.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer
  • Boiling water bath
  • Test tubes
  • Pipettes
  • Centrifuge

Chemical Reagents

  • Fresh oil and repeatedly heated oil
  • TBA reagent (0.67%)
  • Trichloroacetic acid (10%)
  • MDA standards (tetramethoxypropane)

Step-by-Step Practical Procedure

  1. Mix 1 g of each oil with 5 mL TCA solution and 5 mL TBA reagent.
  2. Heat in the boiling bath for 20 minutes; cool and centrifuge.
  3. Read the pink supernatant at 532 nm.
  4. Prepare MDA standards from tetramethoxypropane treated identically.
  5. Express results as mg MDA per kg oil and compare fresh vs heated.

Observations & Expected Results

Heated oil gives a strong pink complex; fresh oil gives only a faint pink, quantifying cumulative oxidation.

Worked Stoichiometric Calculations

Problem: Standard curve: A532 = 0.90 per mg MDA/kg. Heated oil reads 0.45, fresh oil 0.09. Find TBARS values.

Working: Heated: 0.45/0.90 = 0.50 mg MDA/kg; fresh: 0.09/0.90 = 0.10 mg MDA/kg, a fivefold rise with repeated heating.

Safety Precautions & Hazard Control

  • Boil TBA mixtures in a ventilated area.
  • TCA is corrosive; wear gloves.
  • Cool before centrifuging.
  • Use matched cuvettes at 532 nm.

Waste Disposal Protocol

TBA-TCA waste collected as organic chemical waste.

Viva Voce Oral Defense Questions & Answers

Q: What does TBARS actually measure?

A: Malondialdehyde and related aldehydes that react with TBA, i.e. secondary lipid oxidation products.

Q: Why is repeatedly heated oil a health concern?

A: It accumulates oxidised lipids and aldehydes linked to inflammation and chronic disease risk.

← Back to Experiments Directory