Isoelectric Precipitation of Casein from Milk
To isolate casein from milk by precipitation at its isoelectric pH.
Theoretical Foundations
Casein micelles are stable at milk's pH (~6.6) due to negative charge repulsion. Lowering the pH to 4.6 (casein's isoelectric point) neutralises the charge and the micelles aggregate and precipitate, leaving whey proteins in solution.
Required Apparatus & Chemicals
Laboratory Apparatus
- Beaker (250 mL)
- pH meter or pH paper
- Glass rod
- Muslin cloth
- Funnel
- Balance
Chemical Reagents
- Fresh skim milk (100 mL)
- 10% acetic acid
- Distilled water
Step-by-Step Practical Procedure
- Warm 100 mL skim milk to 40 C with gentle stirring.
- Add 10% acetic acid dropwise until pH 4.6, stirring continuously.
- Observe curd formation; let stand 10 minutes.
- Filter through muslin, wash the curd with distilled water.
- Dry and weigh the casein; test the whey filtrate with biuret (positive for whey proteins).
Observations & Expected Results
White curds of casein separate cleanly at pH 4.6; the greenish whey filtrate still gives a faint biuret test.
Worked Stoichiometric Calculations
Problem: 100 mL of skim milk (density 1.03 g/mL) yields 2.7 g of dried casein. What is the % casein w/w?
Working: Mass of milk = 103 g. Casein % = 2.7/103 x 100 = 2.62% w/w, close to the normal ~2.6%.
Safety Precautions & Hazard Control
- Add acid slowly with stirring to avoid local over-acidification.
- Do not boil the milk; 40 C is enough.
- Check pH carefully; overshooting redissolves casein.
- Wash the curd free of whey and acid.
Waste Disposal Protocol
Whey can go down the drain; casein is biodegradable.
Viva Voce Oral Defense Questions & Answers
Q: Why does casein precipitate exactly at pH 4.6?
A: pH 4.6 is casein's isoelectric point, where its net charge is zero and the micelles lose electrostatic repulsion.
Q: Why does the whey still give a biuret test?
A: Whey proteins (lactalbumin, lactoglobulin) stay soluble at pH 4.6 and remain in the filtrate.