Acid Hydrolysis of Starch Followed by Iodine

To follow the acid hydrolysis of starch to glucose by the disappearance of the iodine blue colour and appearance of reducing sugar.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To follow the acid hydrolysis of starch to glucose by the disappearance of the iodine blue colour and appearance of reducing sugar.

Theoretical Foundations

Boiling with dilute HCl hydrolyses starch's glycosidic bonds through dextrins and maltose to glucose. Iodine tracks the loss of long helices (blue to red to colourless) while Benedict's test tracks the gain of reducing ends.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Conical flask
  • Boiling water bath
  • Test tubes
  • White tile
  • Pipettes
  • pH paper

Chemical Reagents

  • 1% starch solution
  • Dilute HCl (1 M)
  • Sodium carbonate solution
  • Iodine solution
  • Benedict's reagent

Step-by-Step Practical Procedure

  1. Boil 50 mL of 1% starch with 5 mL of 1 M HCl in a water bath.
  2. Every 5 minutes, withdraw 2 mL into two tubes: test one drop with iodine on a tile, neutralise the other with Na2CO3 and test with Benedict's.
  3. Record the iodine colour (blue-black to red-brown to yellow) versus time.
  4. Record the Benedict's result (blue to brick red) versus time.
  5. Plot or tabulate both trends to show hydrolysis progress.

Observations & Expected Results

Iodine colour fades from blue-black through reddish to none, while Benedict's test progresses from negative to strongly positive brick red.

Worked Stoichiometric Calculations

Problem: Complete hydrolysis of 0.50 g starch (as (C6H10O5)n, unit M = 162) should yield how many grams of glucose (M = 180)?

Working: Each 162 g of starch unit gains one H2O (18 g) to give 180 g glucose. Yield = 0.50 x 180/162 = 0.556 g of glucose theoretically.

Safety Precautions & Hazard Control

  • Neutralise each aliquot before the Benedict's test; the test needs alkali.
  • Handle boiling acid with care and a holder.
  • Withdraw aliquots with a clean pipette each time.
  • Vent the flask; HCl fumes irritate.

Waste Disposal Protocol

Neutralise the bulk hydrolysate with sodium carbonate before draining with water.

Viva Voce Oral Defense Questions & Answers

Q: Why does the iodine colour pass through red before disappearing?

A: Intermediate dextrins have shorter helices that trap iodine differently, giving red-violet complexes before hydrolysis to achroodextrins and maltose.

Q: Why must the aliquot be neutralised before Benedict's test?

A: Benedict's reagent is alkaline; residual acid would neutralise it and prevent Cu(II) reduction.