Lane-Eynon Titration: Quantitative Estimation of Reducing Sugars
To estimate the reducing sugar content of a sample by titration against standardised Fehling's solution.
Theoretical Foundations
A fixed volume of mixed Fehling's solution is reduced by a standard glucose solution to find the Fehling factor (g glucose equivalent to 10 mL Fehling's). The sample is then titrated into boiling Fehling's with methylene blue as indicator; the endpoint is the disappearance of blue colour.
Required Apparatus & Chemicals
Laboratory Apparatus
- Burette (50 mL)
- Conical flask (250 mL)
- Bunsen burner or hot plate
- Pipettes (10 mL)
- Volumetric flask (250 mL)
Chemical Reagents
- Fehling's A and B
- Standard glucose solution (0.5% w/v)
- Methylene blue indicator (1%)
- Sample sugar solution
- Distilled water
Step-by-Step Practical Procedure
- Pipette 10 mL each of Fehling's A and B into a conical flask and add 40 mL distilled water.
- Fill the burette with standard 0.5% glucose solution.
- Boil the Fehling's mixture, then run in glucose with constant swirling.
- Add 2-3 drops of methylene blue near the endpoint and titrate to complete disappearance of blue (brick-red endpoint).
- Record the titre (V1) and compute the Fehling factor F = (0.5/100) x V1 grams.
- Repeat the titration with the unknown sample (titre V2) and calculate % reducing sugar.
Observations & Expected Results
The deep blue Fehling's mixture turns brick red at the endpoint as methylene blue is decolourised exactly when all Cu(II) is reduced.
Worked Stoichiometric Calculations
Problem: Standardisation: 20.0 mL of 0.5% glucose reduces 10 mL Fehling's. A fruit juice sample (10 mL juice diluted to 100 mL) needs 25.0 mL to reduce the same Fehling's volume. Find the reducing sugar % w/v in the juice.
Working: F = 20.0 x 0.005 = 0.100 g per 10 mL Fehling's. Sugar in 25.0 mL diluted juice = 0.100 g, so diluted juice = 0.100/25.0 x 100 = 0.40 g/100 mL; original juice (10x) = 4.0% w/v reducing sugar.
Safety Precautions & Hazard Control
- Keep the Fehling's mixture boiling throughout the titration.
- Add methylene blue only near the endpoint.
- Titrate briskly; slow titration lets air re-oxidise Cu2O.
- Standardise Fehling's on the same day.
Waste Disposal Protocol
Settle Cu2O, decant liquid to drain with water, and collect the red solid as copper waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the Fehling factor?
A: The mass of glucose (in grams) that exactly reduces a fixed volume (usually 10 mL) of Fehling's solution, found by standardisation.
Q: Why is methylene blue added only near the endpoint?
A: It is itself reduced and decolourised at the endpoint; added earlier it would be consumed prematurely and mask the true endpoint.