CHEMVEN

Effect of Enzyme Concentration on Catalase Rate

To verify first-order dependence of catalase rate on enzyme concentration.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To verify first-order dependence of catalase rate on enzyme concentration.

Theoretical Foundations

At fixed [H2O2], v = k[E]total, so diluting the extract proportionally lowers the O2 evolution rate. This linearity is the basis for using catalase assays to quantify enzyme amount, e.g. comparing tissue extracts.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Gas syringes
  • Conical flasks
  • Water bath at 25 C
  • Pipettes
  • Stopwatch

Chemical Reagents

  • Liver or potato extract dilutions: 1x, 0.5x, 0.25x, 0.125x
  • 3% H2O2
  • Buffer pH 7

Step-by-Step Practical Procedure

  1. Prepare a two-fold dilution series of the extract.
  2. Add 1 mL of each to 20 mL H2O2; collect O2 for 3 min.
  3. Record O2 volume for each dilution.
  4. Plot O2 volume vs relative enzyme concentration.
  5. Check linearity through the origin.

Observations & Expected Results

Typical: O2 volume halves with each two-fold dilution; the plot is linear through the origin.

Worked Stoichiometric Calculations

Problem: O2 volumes: 1x = 48 mL, 0.5x = 24 mL, 0.25x = 12 mL. Verify proportionality.

Working: Ratios 48:24:12 = 4:2:1 match the enzyme ratios: rate proportional to [E] (typical data).

Safety Precautions & Hazard Control

  • Use the same H2O2 batch for all.
  • Start timing at mixing.
  • H2O2 safety precautions.

Waste Disposal Protocol

Dilute peroxide down the sink; tissue to biological waste.

Viva Voce Oral Defense Questions & Answers

Q: Why must [S] be constant here?

A: So that only [E] varies and the rate reflects enzyme amount.

Q: What does deviation from linearity suggest?

A: Substrate depletion, product inhibition, or assay saturation.

Q: How is this used practically?

A: To quantify catalase in unknown samples against a standard.

← Back to Experiments Directory