CHEMVEN

Magnesium Activation of Alkaline Phosphatase

To show that Mg2+ activates alkaline phosphatase using the pNPP assay with and without the metal.

Level: UniversitySafety: Needs supervisionTime: 60 min
Aim of Experiment: To show that Mg2+ activates alkaline phosphatase using the pNPP assay with and without the metal.

Theoretical Foundations

Alkaline phosphatase is a metalloenzyme containing Zn2+ (catalytic) and Mg2+ (structural/activating). Removing Mg2+ (e.g. by dialysis against chelator-free buffer after EDTA treatment, or simply omitting it) lowers activity; re-adding Mg2+ restores it, demonstrating a metal-ion requirement.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer (405 nm)
  • Dialysis tubing
  • Cuvettes
  • Micropipettes

Chemical Reagents

  • Alkaline phosphatase
  • 10 mM pNPP
  • Glycine-NaOH pH 10.4 buffer with and without 1 mM MgCl2
  • 1 mM EDTA (for stripping, careful)

Step-by-Step Practical Procedure

  1. Dialyse phosphatase briefly against EDTA-containing buffer, then against plain buffer (metal-depleted enzyme).
  2. Assay with pNPP in buffer without Mg2+.
  3. Assay with 1 mM MgCl2 added back.
  4. Compare initial slopes.
  5. Calculate percent activation by Mg2+.

Observations & Expected Results

Typical: metal-depleted enzyme shows low activity; adding Mg2+ restores most of it (several-fold activation).

Worked Stoichiometric Calculations

Problem: Slopes: no Mg2+ = 0.08 A/min, + Mg2+ = 0.40 A/min. Calculate activation.

Working: 5-fold activation (0.40/0.08); Mg2+ restores 80%+ of full activity (typical values).

Safety Precautions & Hazard Control

  • Do not over-treat with EDTA (it can strip Zn2+ irreversibly).
  • Use metal-free buffers and plasticware if possible.
  • pNPP blanks at each condition.

Waste Disposal Protocol

p-nitrophenol waste to hazardous organic collection; EDTA buffer down the sink.

Viva Voce Oral Defense Questions & Answers

Q: Which metals does alkaline phosphatase contain?

A: Zn2+ (catalytic) and Mg2+ (activating).

Q: What is a metalloenzyme?

A: An enzyme that requires a metal ion for activity.

Q: Why dialyse after EDTA?

A: To remove the EDTA-metal complex so added Mg2+ is free to rebind.

← Back to Experiments Directory