Blood Glucose Estimation by the GOD-POD Method
To determine blood glucose in a serum sample by the enzymatic GOD-POD end-point method.
Theoretical Foundations
The GOD-POD system is the clinical standard for glucose: glucose oxidase produces H2O2 stoichiometrically from glucose, and peroxidase couples it to a quinoneimine dye (505 nm). Protein is first removed (e.g. with tungstic acid) so only small-molecule glucose reacts.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer (505 nm)
- Centrifuge
- Water bath at 37 C
- Pipettes
Chemical Reagents
- Serum sample
- GOD-POD working reagent
- Glucose standard (100 mg/dL)
- Protein precipitant (tungstic acid, optional)
Step-by-Step Practical Procedure
- Deproteinise serum if required; centrifuge.
- Add 0.02 mL sample/standard to 3 mL reagent.
- Incubate 15 min at 37 C.
- Read A505 vs blank.
- Calculate glucose from the standard.
- Compare with the normal fasting range (70-100 mg/dL).
Observations & Expected Results
Typical: pink colour; normal serum gives A505 near the 100 mg/dL standard.
Worked Stoichiometric Calculations
Problem: A505: standard (100 mg/dL) = 0.40, sample = 0.36. Find blood glucose.
Working: Glucose = 100 x 0.36/0.40 = 90 mg/dL (typical normal value).
Safety Precautions & Hazard Control
- Treat blood/serum as biohazard: gloves, no mouth pipetting.
- Use fresh capillary or venous samples properly.
- Dispose of sharps safely.
Waste Disposal Protocol
Blood-contaminated material to biohazard bags for autoclaving; reagent waste to chemical collection.
Viva Voce Oral Defense Questions & Answers
Q: What is the normal fasting blood glucose range?
A: About 70-100 mg/dL (typical).
Q: Why deproteinise serum?
A: Proteins cause turbidity and side reactions that distort the reading.
Q: Which interferents affect GOD-POD?
A: Ascorbic acid, uric acid, haemolysis, some drugs (typical list).