Desalting by Gel Filtration: Separating Protein from Salt on Sephadex
To separate a protein from ammonium sulphate by size-exclusion chromatography on a Sephadex column.
Theoretical Foundations
In gel filtration, large proteins are excluded from gel pores and elute in the void volume, while small salt ions enter the pores and elute later. Collecting early fractions gives desalted protein; later fractions contain the salt (BaCl2-positive, Biuret-negative).
Required Apparatus & Chemicals
Laboratory Apparatus
- Glass column with Sephadex G-25
- Fraction collector or test tubes
- Peristaltic flow or gravity setup
Chemical Reagents
- Protein in 1 M NaCl / ammonium sulphate (coloured with a trace of blue dextran + phenol red)
- Elution buffer
- BaCl2 solution
- Biuret reagent
Step-by-Step Practical Procedure
- Pack and equilibrate the Sephadex column.
- Apply the sample containing blue dextran (void marker) and phenol red (salt marker).
- Elute with buffer, collecting 2 mL fractions.
- Test fractions: blue colour/Biuret for protein, phenol red/BaCl2 for salt.
- Plot elution profile.
- Pool protein fractions, free of salt.
Observations & Expected Results
Typical: blue protein peak elutes first (void volume), yellow/red salt peak elutes later; the two peaks are baseline-separated.
Worked Stoichiometric Calculations
Problem: Column void volume 15 mL, total volume 45 mL. Protein elutes at 15 mL, salt at 40 mL. Explain.
Working: Protein is excluded (elutes at void volume); salt enters pores and elutes near total volume: classic size exclusion (typical values).
Safety Precautions & Hazard Control
- Do not let the column run dry.
- Apply sample carefully to avoid disturbing the bed.
- Keep flow steady.
Waste Disposal Protocol
Buffer and salt fractions down the sink; gel to solid waste when exhausted.
Viva Voce Oral Defense Questions & Answers
Q: What is the void volume?
A: The elution volume of molecules too large to enter the gel pores.
Q: Why does salt elute later?
A: Small ions explore the pore volume, taking a longer path.
Q: When would you choose dialysis instead?
A: For large volumes or when no column is available; gel filtration is faster.