CHEMVEN

Protein Estimation by the Lowry Method

To estimate protein by the sensitive Lowry method combining Biuret complexation with Folin-Ciocalteu reduction.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To estimate protein by the sensitive Lowry method combining Biuret complexation with Folin-Ciocalteu reduction.

Theoretical Foundations

The Lowry assay has two steps: Cu2+-peptide complex formation in alkali, then reduction of the Folin-Ciocalteu phosphomolybdotungstate reagent by the complex plus tyrosine/tryptophan residues, giving intense blue colour at 750 nm. It is ~100x more sensitive than Biuret but sensitive to many interfering substances.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer (750 nm)
  • Test tubes
  • Pipettes
  • Cuvettes
  • Vortex mixer

Chemical Reagents

  • BSA standards: 0-0.5 mg/mL
  • Lowry reagent A (alkaline copper)
  • Folin-Ciocalteu reagent (1 N)
  • Unknown protein sample

Step-by-Step Practical Procedure

  1. Add 5 mL reagent A to 1 mL standard/unknown; stand 10 min.
  2. Add 0.5 mL Folin reagent rapidly with immediate mixing.
  3. Stand 30 min for full colour development.
  4. Read A750.
  5. Plot the BSA standard curve and read the unknown.

Observations & Expected Results

Typical: deep blue colour proportional to protein; linear range ~0.05-0.5 mg/mL. Unknown falls within the curve.

Worked Stoichiometric Calculations

Problem: Standard curve: A750 = 1.60 x C (mg/mL). Unknown A750 = 0.48. Find concentration.

Working: C = 0.48/1.60 = 0.30 mg/mL (typical illustrative value).

Safety Precautions & Hazard Control

  • Add Folin reagent quickly with instant mixing; timing matters.
  • Folin reagent is acidic and corrosive.
  • Avoid detergents, reducing agents and Tris in samples (they interfere).

Waste Disposal Protocol

Molybdenum/tungsten waste: collect as heavy-metal aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is Lowry more sensitive than Biuret?

A: Signal amplification: Folin reduction by Tyr/Trp adds to the copper-peptide colour.

Q: Name two interferents in the Lowry assay.

A: Detergents (SDS), reducing agents (DTT, mercaptoethanol), Tris buffer, EDTA.

Q: At what wavelength is Lowry read?

A: 750 nm (typical).

← Back to Experiments Directory