pH Optimum of Urease
To determine the pH optimum of urease by Nessler ammonia estimation at different pH values.
Theoretical Foundations
Urease shows a pH optimum near 7.0-7.4. Activity is quantified by the ammonia released, measured colorimetrically with Nessler reagent (yellow-brown complex, 425 nm) after stopping the reaction. The bell-shaped curve reflects ionisation of active-site groups.
Required Apparatus & Chemicals
Laboratory Apparatus
- Spectrophotometer (425 nm)
- Cuvettes
- Water bath at 37 C
- Test tubes
- pH meter
- Pipettes
Chemical Reagents
- Seed urease extract
- 2% urea in buffers pH 5, 6, 7, 8, 9
- Nessler reagent
- Trichloroacetic acid (5%) to stop reaction
Step-by-Step Practical Procedure
- Prepare urea solutions buffered at pH 5-9.
- Add extract, incubate exactly 15 min at 37 C.
- Stop with trichloroacetic acid and filter.
- Develop colour with Nessler reagent; read A425.
- Convert to micromol NH3 using an ammonium standard curve.
- Plot activity vs pH.
Observations & Expected Results
Typical: maximum ammonia near pH 7, lower on both sides; the curve is bell-shaped with optimum ~pH 7.0-7.4.
Worked Stoichiometric Calculations
Problem: A425 = 0.60 corresponds to 30 micromol NH3 per tube from 1 mL extract in 15 min. Find activity in U/mL.
Working: 30 micromol NH3 = 15 micromol urea hydrolysed in 15 min = 1.0 micromol/min = 1.0 U per mL (typical illustrative value).
Safety Precautions & Hazard Control
- Nessler reagent contains mercury; wear gloves, no sink disposal.
- Stop all tubes at exactly the same time.
- Keep incubation at 37 C.
Waste Disposal Protocol
Nessler waste is mercury waste: collect in labelled hazardous containers, never down the sink.
Viva Voce Oral Defense Questions & Answers
Q: What does Nessler reagent detect?
A: Ammonia, as a yellow-brown colloidal complex.
Q: Why stop the reaction with acid?
A: To denature urease instantly and fix the time point.
Q: Why is Nessler waste special?
A: It contains mercury(II), a cumulative toxin needing hazardous collection.