Effect of Substrate Concentration on Catalase: Km for Hydrogen Peroxide

To determine Km and Vmax of catalase for H2O2 by measuring initial O2 evolution rates.

Level: UniversitySafety: Needs supervisionTime: 2 h
Aim of Experiment: To determine Km and Vmax of catalase for H2O2 by measuring initial O2 evolution rates.

Theoretical Foundations

Catalase follows Michaelis-Menten kinetics with a very high Km for H2O2 (tens of mM), meaning it is rarely saturated in vivo and its rate tracks peroxide concentration. Initial rates of O2 evolution at several [H2O2] give v vs [S]; the Lineweaver-Burk plot yields Km and Vmax.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Gas syringes
  • Conical flasks
  • Water bath at 25 C
  • Stopwatches
  • Volumetric flasks
  • Pipettes

Chemical Reagents

  • H2O2 solutions: 0.01, 0.02, 0.05, 0.10, 0.20 M in pH 7 buffer
  • Dilute potato or liver extract
  • Distilled water

Step-by-Step Practical Procedure

  1. Prepare five H2O2 concentrations in pH 7 buffer at 25 C.
  2. Add a fixed volume of dilute extract to 20 mL of each; start timing.
  3. Record O2 volume at 30 s intervals for 3 min.
  4. Take the initial slope (mL O2/min) as v for each [S].
  5. Plot 1/v vs 1/[S]; determine slope and intercept.
  6. Calculate Vmax and Km.

Observations & Expected Results

Typical: v rises with [H2O2] and begins to plateau; the double-reciprocal plot is linear. Km is typically tens of mM, Vmax depends on extract dilution.

Worked Stoichiometric Calculations

Problem: Lineweaver-Burk slope = 0.80 min/mM (in rate units used) and intercept = 0.020 (same units). Find Km and Vmax.

Working: Vmax = 1/0.020 = 50 rate units. Km = slope x Vmax = 0.80 x 50 = 40 mM (typical illustrative values).

Safety Precautions & Hazard Control

  • Use initial slopes only; H2O2 depletes fast.
  • Standardise H2O2 stock by titration if possible.
  • Keep extract dilute so rates are measurable.
  • Temperature control is essential.

Waste Disposal Protocol

Dilute peroxide mixtures down the sink; tissue extract to biological waste.

Viva Voce Oral Defense Questions & Answers

Q: Why is catalase Km for H2O2 so high?

A: So the enzyme is not saturated and can respond proportionally to rising peroxide levels.

Q: What are the units of Vmax here?

A: mL O2 per min (per fixed enzyme amount), convertible to micromol/min.

Q: Why use initial rates?

A: To avoid substrate depletion and product effects distorting v.

← Back to Experiments Directory