Effect of Temperature on Salivary Amylase Activity
To determine the optimum temperature of salivary amylase by measuring the time to the achromic point at different temperatures.
Theoretical Foundations
Enzyme rate rises with temperature (roughly doubling per 10 C, Q10 ~ 2) as molecular collisions increase, but above the optimum the protein denatures and activity falls. The temperature giving the shortest achromic time is the optimum. Denaturation is usually irreversible for amylase.
Required Apparatus & Chemicals
Laboratory Apparatus
- Test tubes (12)
- Water baths / beakers at 0, 20, 37, 50, 70 C
- Thermometers
- Spotting tile
- Droppers
- Stopwatch
- Ice bath
Chemical Reagents
- 1% starch solution
- Diluted saliva (1:10)
- Iodine solution
- Distilled water
- Ice
Step-by-Step Practical Procedure
- Set up five water baths at 0, 20, 37, 50 and 70 C.
- Equilibrate 5 mL starch tubes and saliva tubes at each temperature for 10 min.
- Mix starch and saliva at each temperature and start timing.
- Test drops with iodine every 1-2 min until the achromic point.
- Record achromic time for each temperature.
- Calculate relative activity as 1/(achromic time) and plot against temperature.
Observations & Expected Results
Typical: activity rises from 0 to 37 C, peaks near 37 C, then falls sharply; at 70 C no colour loss occurs. The 1/time vs temperature plot is bell-shaped.
Worked Stoichiometric Calculations
Problem: Achromic times: 20 C = 20 min, 30 C = 10 min. Estimate Q10 between 20 and 30 C.
Working: Rate is proportional to 1/time. k30/k20 = 20/10 = 2. Q10 = (k2/k1)^(10/(T2-T1)) = 2^(10/10) = 2.0 (typical value).
Safety Precautions & Hazard Control
- Equilibrate both solutions fully before mixing.
- Maintain each bath temperature within 1 C.
- Use the same saliva dilution for all tubes.
- Stir gently; do not froth the enzyme.
Waste Disposal Protocol
Pour aqueous mixtures down the sink; discard any broken glass in sharps bins.
Viva Voce Oral Defense Questions & Answers
Q: Why does activity fall above the optimum?
A: Thermal denaturation disrupts the tertiary structure and the active site geometry.
Q: Why is the optimum near 37 C for salivary amylase?
A: It evolved to work at human body temperature.
Q: What is Q10?
A: The factor by which the rate changes for a 10 C rise in temperature.