Biochemical Oxygen Demand (BOD) of Wastewater

To determine the 5-day BOD of a wastewater sample.

Level: UniversitySafety: Needs supervisionTime: 5 days (incubation)
Aim of Experiment: To determine the 5-day BOD of a wastewater sample.

Theoretical Foundations

BOD5 is the oxygen consumed by microorganisms oxidising organic matter in 5 days at 20 C; it measures biodegradable pollution. Dissolved oxygen is fixed by the Winkler method (MnSO4 + alkaline KI, then acid) initially and after incubation, and titrated with thiosulphate. The difference, times the dilution factor, gives BOD in mg/L.

Required Apparatus & Chemicals

Laboratory Apparatus

  • BOD bottles (300 mL)
  • Incubator (20 C)
  • Burette
  • Pipettes

Chemical Reagents

  • Wastewater sample (dilutions 1%, 5%, 25%)
  • Dilution water (aerated, seeded)
  • Manganous sulphate solution
  • Alkaline potassium iodide
  • Concentrated sulphuric acid
  • 0.025 N sodium thiosulphate
  • Starch indicator

Step-by-Step Practical Procedure

  1. Prepare dilutions of the sample in aerated dilution water (e.g. 1%, 5%, 25%).
  2. Fill BOD bottles completely, stopper without air bubbles.
  3. Fix DO in two bottles immediately (Winkler): add MnSO4, then alkaline KI, shake, settle, acidify.
  4. Titrate the liberated iodine with 0.025 N thiosulphate (DO initial).
  5. Incubate the remaining bottles 5 days at 20 C in the dark, then fix and titrate (DO final).
  6. Calculate BOD = (DO initial - DO final) x dilution factor.

Observations & Expected Results

Domestic sewage gives BOD 200-300 mg/L; treated effluent must be under 30 mg/L.

Worked Stoichiometric Calculations

Problem: A 5% dilution showed initial DO 8.0 mg/L and final DO 3.0 mg/L. Calculate the BOD5.

Working: Depletion = 8.0 - 3.0 = 5.0 mg/L. Dilution factor = 100/5 = 20. BOD5 = 5.0 x 20 = 100 mg/L.

Safety Precautions & Hazard Control

  • Exclude all air bubbles when stoppering BOD bottles.
  • Incubate in complete darkness to stop photosynthesis.
  • Use seeded dilution water for industrial wastes lacking microbes.
  • Keep incubation at exactly 20 C.

Waste Disposal Protocol

Titrated samples go down the drain; incubated bottles are disinfected before disposal.

Viva Voce Oral Defense Questions & Answers

Q: Why 5 days at 20 C?

A: The standard adopted historically: 5 days was the longest river travel time in England, and 20 C is a typical summer river temperature.

Q: What is the Winkler method?

A: Dissolved oxygen oxidises Mn(OH)2 to MnO2, which in acid liberates iodine from KI, titrated with thiosulphate.