Mixed Liquor Suspended Solids (MLSS) in Aeration Tanks
To determine MLSS and MLVSS of activated sludge.
Theoretical Foundations
MLSS is the biomass concentration in the aeration tank (TSS of mixed liquor), typically 2000-4000 mg/L; MLVSS (volatile fraction at 550 C) approximates active biomass, typically 70-80% of MLSS. Operators use MLSS to control the food-to-microorganism (F/M) ratio and sludge age.
Required Apparatus & Chemicals
Laboratory Apparatus
- Filtration assembly
- Glass-fibre filters
- Oven
- Muffle furnace
- Analytical balance
Chemical Reagents
- Distilled water (filter washing)
- Silica gel (desiccant)
- Dilute HCl (glassware cleaning)
Step-by-Step Practical Procedure
- Weigh a prepared glass-fibre filter.
- Filter 50 mL of well-mixed mixed liquor.
- Dry at 103 C, cool, weigh: MLSS.
- Ignite at 550 C, cool, weigh: loss = MLVSS.
- Express both as mg/L.
- Compute the volatile fraction and comment on biomass health.
Observations & Expected Results
Brown flocculent biomass on the filter; healthy MLVSS/MLSS ~0.7-0.8.
Worked Stoichiometric Calculations
Problem: 50 mL of mixed liquor gave 150 mg dried solids and 110 mg volatile loss. Calculate MLSS and MLVSS.
Working: MLSS = 150 x 1000/50 = 3000 mg/L. MLVSS = 110 x 1000/50 = 2200 mg/L. Volatile fraction 73% - healthy biomass at a normal operating concentration.
Safety Precautions & Hazard Control
- Sample from a well-mixed zone of the tank.
- Filter promptly; biomass respires.
- Dry/ignite to constant weight.
- Use a representative volume (25-100 mL).
Waste Disposal Protocol
Dried biomass to solid waste.
Viva Voce Oral Defense Questions & Answers
Q: What is the F/M ratio?
A: Food (BOD load) to microorganism (MLVSS) ratio per day; typically 0.2-0.5 /day for conventional activated sludge.
Q: Why is MLVSS a better biomass measure than MLSS?
A: It excludes inert inorganic solids, approximating the living organic fraction.
Q: What happens if MLSS is too high?
A: Poor settling, oxygen shortage and clarifier overloading; wasting must be increased.