Sedimentation: Column Settling Test for Suspensions

To determine the settling velocity distribution of suspended solids in a settling column.

Level: UniversitySafety: SafeTime: 2 h
Aim of Experiment: To determine the settling velocity distribution of suspended solids in a settling column.

Theoretical Foundations

In a tall column, samples withdrawn from a fixed depth at intervals show falling suspended-solids concentration as particles settle past the sampling port. Percent removal vs time gives the settling velocity distribution; the design overflow rate of a clarifier equals the settling velocity of the target particle. Discrete (Type I) settling applies to grit-like particles.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Settling column (2 m) with sampling ports
  • TSS filtration set
  • Oven
  • Stopwatch

Chemical Reagents

  • No chemicals (physical settling test)
  • Distilled water (column rinsing)
  • Laboratory detergent

Step-by-Step Practical Procedure

  1. Fill the column uniformly with the mixed suspension.
  2. At time zero, withdraw a port sample for initial TSS (C0).
  3. Withdraw port samples at 5, 15, 30, 60, 120 minutes.
  4. Determine TSS of each sample gravimetrically.
  5. Compute percent remaining (C/C0 x 100) vs time.
  6. Calculate settling velocities = port depth / time for chosen removal percentages.

Observations & Expected Results

Supernatant clears from the top down; coarse particles settle in minutes, fines take hours.

Worked Stoichiometric Calculations

Problem: Port depth 1.5 m; 50% removal reached at 30 min. Calculate the settling velocity and the corresponding clarifier overflow rate.

Working: Velocity = 1.5 m / 0.5 h = 3.0 m/h. Design overflow rate = 3.0 m/h = 72 m/day for 50% removal of this suspension.

Safety Precautions & Hazard Control

  • Mix the column uniformly at time zero.
  • Withdraw samples gently without turbulence.
  • Keep the column vertical and vibration-free.
  • Temperature must be constant (viscosity affects settling).

Waste Disposal Protocol

Suspension may go to drain; filters to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: What is the overflow rate of a clarifier?

A: Flow divided by surface area (m/day); particles settling faster than this rate are removed.

Q: Distinguish Type I and Type II settling.

A: Type I: discrete particles settle independently (grit); Type II: flocculent particles agglomerate and settle faster as they fall.

Q: Why does temperature matter?

A: Water viscosity falls with rising temperature, so particles settle faster in warm water.