CHEMVEN

Dustfall: Settleable Particulate Measurement

To measure dustfall rate using deposit gauges exposed for one month.

Level: UniversitySafety: SafeTime: 30 min (plus 30-day exposure)
Aim of Experiment: To measure dustfall rate using deposit gauges exposed for one month.

Theoretical Foundations

An open jar/vessel of known mouth area collects settleable dust for 30 days; the dried residue weighed gives dustfall in tonnes/km2/month (or mg/m2/day). It is a simple nuisance-dust indicator near crushers, cement plants and mines. Typical urban background: 5-15 tonnes/km2/month; near sources: >25.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Dustfall jars (standard design) with stands
  • Oven
  • Desiccator
  • Analytical balance
  • Distilled water

Chemical Reagents

  • Copper sulphate solution (algaecide, optional)
  • Distilled water
  • Laboratory detergent

Step-by-Step Practical Procedure

  1. Weigh clean dry jars; add a little distilled water with algaecide.
  2. Mount jars at 2-3 m height at chosen sites for 30 days.
  3. Retrieve jars; rinse all deposits into the jar.
  4. Evaporate to dryness, dry at 105 C, cool and weigh.
  5. Compute dustfall = mass gain / mouth area / 30 days.
  6. Compare upwind, downwind and background sites.

Observations & Expected Results

Visible gritty deposit. Cement-plant downwind: 30-80 tonnes/km2/month.

Worked Stoichiometric Calculations

Problem: Jar mouth area 0.02 m2 collected 12 g in 30 days. Calculate dustfall in tonnes/km2/month.

Working: 12 g / 0.02 m2 = 600 g/m2/month = 600 tonnes/km2/month? No: 1 g/m2 = 1 tonne/km2, so 600 g/m2 = 600 tonnes/km2/month. That is extremely high - check: 12 g over 0.02 m2 = 600 g/m2. Yes, 600 tonnes/km2/month, indicating a severe dust nuisance needing control.

Safety Precautions & Hazard Control

  • Secure jars against toppling and vandalism.
  • Prevent bird interference (spikes/perches design).
  • Record any disturbance of the gauge.
  • Dry to constant weight.

Waste Disposal Protocol

Dried dust to solid waste.

Viva Voce Oral Defense Questions & Answers

Q: What particle sizes does dustfall measure?

A: Coarse settleable particles, roughly >10-20 um, that deposit by gravity - not the respirable fraction.

Q: Why add an algaecide?

A: To prevent algal growth in the collected water, which would add biological mass to the dust weight.

Q: How does dustfall differ from SPM?

A: Dustfall measures deposition flux (nuisance); SPM measures airborne concentration (health).