CHEMVEN

Nitrogen Dioxide in Air: Jacob-Hochheiser Method

To determine ambient nitrogen dioxide by the Jacob-Hochheiser (sodium arsenite) method.

Level: UniversitySafety: Needs supervisionTime: 2 h (plus 24 h sampling)
Aim of Experiment: To determine ambient nitrogen dioxide by the Jacob-Hochheiser (sodium arsenite) method.

Theoretical Foundations

Air is bubbled through sodium hydroxide-sodium arsenite absorbing solution, converting NO2 to nitrite. The nitrite is diazotised with sulphanilamide and coupled with NEDA to form a pink azo dye measured at 540 nm. Indian NAAQS for NO2 (24-h): 80 ug/m3; WHO 2021 guideline: 25 ug/m3.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Midget impingers
  • Calibrated air pump
  • Spectrophotometer (540 nm)
  • Volumetric flasks
  • Stopwatch

Chemical Reagents

  • Sodium hydroxide-sodium arsenite absorbing solution
  • Sulphanilamide reagent
  • NEDA solution
  • Hydrogen peroxide (oxidation check, optional)
  • Sodium nitrite stock standard

Step-by-Step Practical Procedure

  1. Fill impingers with the absorbing solution.
  2. Sample air at 0.2-0.5 L/min for 24 hours.
  3. Transfer the solution to a volumetric flask.
  4. Add sulphanilamide, wait, then NEDA; a pink dye develops.
  5. Measure absorbance at 540 nm after 15 minutes.
  6. Read NO2 from a nitrite calibration curve (x 0.82 sampling efficiency factor if applicable) and divide by air volume.

Observations & Expected Results

Pink dye. Traffic junctions: 40-120 ug/m3 NO2.

Worked Stoichiometric Calculations

Problem: Impinger analysis gives 30 ug NO2; air volume 0.50 m3. Calculate NO2 and check the 80 ug/m3 NAAQS.

Working: NO2 = 30/0.50 = 60 ug/m3. Below the 80 ug/m3 NAAQS but above the WHO 2021 guideline of 25 ug/m3.

Safety Precautions & Hazard Control

  • Arsenite absorbing solution is toxic; wear gloves.
  • Protect the solution from light during sampling.
  • Keep colour-development timing constant.
  • Calibrate the pump before and after sampling.

Waste Disposal Protocol

Arsenite waste goes to the hazardous inorganic waste container.

Viva Voce Oral Defense Questions & Answers

Q: What does the arsenite do in the absorbing solution?

A: It retains NO2 as nitrite and prevents its oxidation, stabilising the sample.

Q: Why is this method specific for NO2 among nitrogen oxides?

A: NO is not absorbed efficiently; only NO2 (and N2O3/N2O4) converts to nitrite in the alkali.

Q: Name a health effect of NO2.

A: Airway inflammation and increased respiratory infections; it is also a precursor of ground-level ozone.

← Back to Experiments Directory