Total Suspended Solids: Gravimetric Determination

To determine total suspended solids (TSS) in wastewater by glass-fibre filtration and gravimetry.

Level: UniversitySafety: SafeTime: 90 min
Aim of Experiment: To determine total suspended solids (TSS) in wastewater by glass-fibre filtration and gravimetry.

Theoretical Foundations

A measured sample volume is filtered through a pre-weighed glass-fibre filter (0.7-1.2 um); the residue dried at 103-105 C is weighed. TSS (mg/L) = (weight gain in mg x 1000) / sample volume in mL. Discharge standards commonly limit TSS to 100 mg/L (inland surface waters); raw sewage is typically 150-400 mg/L.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Filtration assembly with vacuum pump
  • Glass-fibre filter discs (pre-weighed)
  • Drying oven (103 C)
  • Desiccator
  • Analytical balance

Chemical Reagents

  • Distilled water (filter washing)
  • Silica gel desiccant (for desiccator)
  • Laboratory detergent (glassware cleaning)

Step-by-Step Practical Procedure

  1. Dry filter discs at 103-105 C, cool in a desiccator, and weigh (W1).
  2. Filter a well-mixed measured volume (100-500 mL) under vacuum.
  3. Wash the residue with distilled water.
  4. Dry the filter at 103-105 C for 1 hour.
  5. Cool in a desiccator and weigh (W2); repeat drying to constant weight.
  6. TSS = (W2 - W1) mg x 1000 / sample mL.

Observations & Expected Results

Visible residue on filter. Raw sewage: 150-400 mg/L; treated effluent: <30 mg/L typically.

Worked Stoichiometric Calculations

Problem: 250 mL of effluent gave a filter weight gain of 18.5 mg. Calculate TSS and check a 100 mg/L discharge limit.

Working: TSS = 18.5 x 1000 / 250 = 74 mg/L. Below the 100 mg/L discharge limit; compliant.

Safety Precautions & Hazard Control

  • Shake the sample well; solids settle fast.
  • Dry to constant weight.
  • Handle filters with forceps, not fingers.
  • Choose a sample volume giving 10-200 mg residue.

Waste Disposal Protocol

Dried filters with residue go to solid lab waste.

Viva Voce Oral Defense Questions & Answers

Q: Why glass-fibre and not paper filters?

A: Glass-fibre filters have a defined fine pore size, withstand 103 C drying, and give low, stable blank weights.

Q: Why dry at 103-105 C specifically?

A: Hot enough to remove water but not so hot as to volatilise organic matter or decompose bicarbonates significantly.

Q: How do TSS and turbidity differ?

A: TSS is a mass concentration (mg/L) by weighing; turbidity is an optical property (NTU) - related but not identical.