CHEMVEN

Acidity of Water: Two-Stage Titration

To determine methyl orange and phenolphthalein acidity of an industrial effluent.

Level: UniversitySafety: Needs supervisionTime: 45 min
Aim of Experiment: To determine methyl orange and phenolphthalein acidity of an industrial effluent.

Theoretical Foundations

Acidity is the base-neutralising capacity of water. Titration with standard NaOH to pH 3.7 (methyl orange endpoint) measures mineral (strong-acid) acidity; continued titration to pH 8.3 (phenolphthalein endpoint) measures total acidity including weak acids like CO2 and organic acids. Acidity (mg/L as CaCO3) = V x N x 50000 / sample volume. Acid mine drainage may show acidity of hundreds of mg/L.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Burette
  • Pipettes
  • Conical flasks
  • pH meter (optional for endpoints)

Chemical Reagents

  • Sodium hydroxide (0.02 N, standardised)
  • Methyl orange indicator
  • Phenolphthalein indicator

Step-by-Step Practical Procedure

  1. Take 100 mL of sample in a conical flask.
  2. Add methyl orange; if the solution is already yellow, mineral acidity is zero - record and continue.
  3. Titrate with 0.02 N NaOH to the methyl orange endpoint (orange); record V1.
  4. Add phenolphthalein and continue titration to the first permanent pink; record total V2.
  5. Calculate mineral acidity = V1 x N x 50000/100 and total acidity = V2 x N x 50000/100 mg/L as CaCO3.
  6. CO2 acidity = total - mineral acidity.

Observations & Expected Results

Mine drainage: pH 2-4, acidity 100-1000 mg/L as CaCO3; natural waters usually show only CO2 acidity.

Worked Stoichiometric Calculations

Problem: 100 mL of mine water: V1 = 4.0 mL, V2 = 14.0 mL of 0.02 N NaOH. Calculate mineral and total acidity.

Working: Mineral acidity = 4.0 x 0.02 x 50000/100 = 40 mg/L; total acidity = 14.0 x 0.02 x 50000/100 = 140 mg/L as CaCO3. CO2/weak-acid acidity = 100 mg/L. The water is strongly acidic and needs neutralisation (e.g. lime dosing).

Safety Precautions & Hazard Control

  • Titrate promptly; CO2 exchanges with air and changes weak-acid acidity.
  • Do not overshoot the methyl orange endpoint.
  • Standardise NaOH against potassium hydrogen phthalate.
  • Wear gloves; the sample may be strongly acidic.

Waste Disposal Protocol

Neutralised titration mixtures may go down the drain.

Viva Voce Oral Defense Questions & Answers

Q: Distinguish mineral acidity from CO2 acidity.

A: Mineral acidity (to pH 3.7) is from strong acids like H2SO4; CO2 acidity (pH 3.7 to 8.3) is from dissolved CO2 and weak organic acids.

Q: Why is acidity expressed as CaCO3?

A: To give a common equivalent basis for comparing acidic waters, mirroring the alkalinity convention.

Q: What causes acid mine drainage?

A: Oxidation of pyrite (FeS2) in exposed mine workings produces sulphuric acid and dissolved iron.

← Back to Experiments Directory