CHEMVEN

Phenols in Water: 4-Aminoantipyrine Method

To determine phenolic compounds in industrial wastewater by the 4-aminoantipyrine method.

Level: UniversitySafety: Advanced lab onlyTime: 90 min
Aim of Experiment: To determine phenolic compounds in industrial wastewater by the 4-aminoantipyrine method.

Theoretical Foundations

Phenols react with 4-aminoantipyrine in the presence of potassium ferricyanide at pH 10 to form a red antipyrine dye, extracted into chloroform and measured at 460 nm. Phenols are toxic to fish at ~1 mg/L and impart a medicinal taste to chlorinated drinking water at just 0.002 mg/L. The method needs prior distillation to separate phenols from interferences.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Distillation apparatus
  • Separating funnel
  • Spectrophotometer (460 nm)
  • pH meter

Chemical Reagents

  • 4-aminoantipyrine solution
  • Potassium ferricyanide solution
  • Ammonium hydroxide buffer (pH 10)
  • Chloroform
  • Phenol stock standard
  • Phosphoric acid (for distillation)

Step-by-Step Practical Procedure

  1. Acidify 500 mL sample with phosphoric acid and distil, collecting 500 mL distillate.
  2. Adjust the distillate to pH 10 with ammonium hydroxide buffer.
  3. Add 4-aminoantipyrine and potassium ferricyanide; mix.
  4. Extract the red dye into chloroform.
  5. Measure absorbance at 460 nm against a blank.
  6. Read phenol from a calibration curve prepared identically.

Observations & Expected Results

Red dye in chloroform proportional to phenol. Coke-oven/petrochemical effluents: 10-1000 mg/L; discharge limit commonly 1 mg/L.

Worked Stoichiometric Calculations

Problem: A distillate extract gives A = 0.44 at 460 nm; calibration A = 0.88 x C (mg/L phenol). Find phenol and check a 1 mg/L discharge limit.

Working: C = 0.44/0.88 = 0.50 mg/L phenol. Below the 1 mg/L discharge limit, but note that chlorination of such water would still cause taste problems at this level.

Safety Precautions & Hazard Control

  • Phenol is corrosive and toxic by skin absorption; wear gloves.
  • Distil in a fume hood.
  • Chloroform extracts go to halogenated waste.
  • Keep pH at 10 +/- 0.2 for full colour development.

Waste Disposal Protocol

Chloroform and phenol-containing residues go to the hazardous organic waste container.

Viva Voce Oral Defense Questions & Answers

Q: Why is distillation done before colour development?

A: It separates volatile phenols from coloured matter, oxidants and other interferences in the wastewater matrix.

Q: Why do traces of phenol ruin chlorinated drinking water?

A: Chlorine converts phenols to chlorophenols, which have an intense medicinal taste detectable at 0.002 mg/L.

Q: What is the role of potassium ferricyanide?

A: It is the oxidant that couples 4-aminoantipyrine with phenol to form the red dye.

← Back to Experiments Directory