CHEMVEN

Manganese in Water: Periodate Oxidation Method

To determine manganese in water by persulphate/periodate oxidation to permanganate.

Level: UniversitySafety: Advanced lab onlyTime: 60 min
Aim of Experiment: To determine manganese in water by persulphate/periodate oxidation to permanganate.

Theoretical Foundations

Manganese is oxidised to purple permanganate (MnO4-) by potassium periodate in hot nitric acid; absorbance at 525 nm is proportional to manganese. WHO guideline: 0.4 mg/L (health-based); manganese causes black staining and, at high chronic intake, neurological effects.

Required Apparatus & Chemicals

Laboratory Apparatus

  • Spectrophotometer (525 nm)
  • Hot plate
  • Beakers
  • Volumetric flasks

Chemical Reagents

  • Potassium periodate
  • Concentrated nitric acid
  • Potassium permanganate stock (Mn standard)
  • Hydroxylamine (for blank check, optional)

Step-by-Step Practical Procedure

  1. Take 100 mL sample, add 5 mL conc. HNO3 and evaporate to a small volume to destroy organics.
  2. Add potassium periodate and heat until the purple permanganate colour develops fully.
  3. Cool, transfer to a 100 mL flask and make up to the mark.
  4. Prepare standards by oxidising known Mn solutions identically.
  5. Measure absorbance at 525 nm against a reagent blank.
  6. Read manganese from the calibration curve.

Observations & Expected Results

Purple permanganate colour. WHO guideline 0.4 mg/L; black MnO2 deposits in pipes above ~0.1 mg/L.

Worked Stoichiometric Calculations

Problem: A sample gives A = 0.22 at 525 nm; calibration A = 1.10 x C (mg/L Mn). Find manganese and comment.

Working: C = 0.22/1.10 = 0.20 mg/L Mn. Below the WHO guideline of 0.4 mg/L but high enough to cause black staining of fixtures over time.

Safety Precautions & Hazard Control

  • Destroy organic matter completely; it reduces permanganate back to Mn2+.
  • Heat in a fume hood; nitric acid fumes are toxic.
  • Cool before making up to volume.
  • Chloride above 100 mg/L interferes; remove by evaporation with HNO3.

Waste Disposal Protocol

Acidic permanganate waste: reduce with sodium bisulphite, neutralise, then drain.

Viva Voce Oral Defense Questions & Answers

Q: Why is organic matter destroyed before oxidation?

A: Organics reduce the formed permanganate back to colourless Mn2+, bleaching the colour being measured.

Q: What oxidation state change occurs?

A: Mn2+ is oxidised to MnO4- (Mn(VII)), a 5-electron oxidation.

Q: Name a neurological concern of chronic manganese exposure.

A: Manganism, a Parkinson-like disorder from long-term high inhalation or ingestion exposure.

← Back to Experiments Directory