Total Hardness of Water: EDTA Complexometric Titration
To determine the total hardness (as CaCO3) of a water sample by EDTA titration.
Theoretical Foundations
Hardness is caused mainly by calcium and magnesium ions. EDTA forms stable 1:1 complexes with Ca2+ and Mg2+ at pH 10 (ammonia buffer). Eriochrome Black T indicator forms a wine-red complex with the metal ions and is displaced by EDTA, turning blue at the endpoint. Hardness (mg/L as CaCO3) = V x N x 50000 / sample volume. WHO guideline: 200 mg/L (taste threshold); values above 500 mg/L are generally considered very hard.
Required Apparatus & Chemicals
Laboratory Apparatus
- Burette 50 mL
- Pipettes
- Conical flask 250 mL
- Measuring cylinder
- pH paper
Chemical Reagents
- EDTA solution (0.01 M, standardised)
- Ammonia-ammonium chloride buffer (pH 10)
- Eriochrome Black T indicator
- Standard calcium solution (for standardisation)
Step-by-Step Practical Procedure
- Take 50 mL of the water sample in a conical flask.
- Add 1-2 mL of pH 10 ammonia buffer.
- Add 2-3 drops of Eriochrome Black T indicator; the solution turns wine red.
- Titrate with 0.01 M EDTA, swirling, until the colour changes sharply from wine red to pure blue.
- Record the titre; repeat to concordance.
- Calculate total hardness as CaCO3 = V(EDTA) x M x 100000 / 50 (or V x N x 50000 / V_sample).
Observations & Expected Results
Wine-red to clear blue endpoint. Classification: 0-75 soft, 75-150 moderately hard, 150-300 hard, >300 very hard (mg/L as CaCO3). WHO guideline value 200 mg/L.
Worked Stoichiometric Calculations
Problem: 50 mL of tap water required 11.6 mL of 0.01 M EDTA. Calculate total hardness as mg/L CaCO3.
Working: Hardness = V x M x 100000 / sample mL = 11.6 x 0.01 x 100000 / 50 = 11.6 x 20 = 232 mg/L as CaCO3 (hard water).
Safety Precautions & Hazard Control
- Maintain pH at 10 +/- 0.1; the indicator fails outside this range.
- Use freshly prepared indicator solution (it degrades).
- Heavy metals (Fe, Cu) block the indicator; add masking agents if present.
- Titrate slowly near the endpoint for a sharp colour change.
Waste Disposal Protocol
The titrated solutions contain only dilute buffer and EDTA; they may go down the drain with excess water.
Viva Voce Oral Defense Questions & Answers
Q: Why is the titration done at pH 10?
A: EDTA complexes Ca2+ and Mg2+ quantitatively at pH 10, and Eriochrome Black T shows its proper colour change only in this pH range.
Q: Why does the indicator change colour at the endpoint?
A: EDTA has a higher formation constant with the metal ions than the indicator does, so it strips the metal from the red metal-indicator complex, releasing the free blue indicator.
Q: Express 232 mg/L hardness in degrees Clark and French degrees.
A: Degrees Clark = 232/14.3 = 16.2; French degrees = 232/10 = 23.2.