Biochemical Oxygen Demand: 5-Day BOD Test
To determine the 5-day biochemical oxygen demand (BOD5) of a wastewater sample at 20 C.
Theoretical Foundations
BOD is the amount of oxygen consumed by microorganisms while biodegrading organic matter in a sample over 5 days at 20 C in the dark (BOD5). It is the standard index of biodegradable pollution load. The sample is diluted with seeded, oxygen-saturated dilution water, and DO is measured before and after incubation by Winkler titration. BOD (mg/L) = (D1 - D2) x dilution factor. Domestic sewage typically shows BOD 100-300 mg/L; treated effluent should be below 30 mg/L (common discharge standard).
Required Apparatus & Chemicals
Laboratory Apparatus
- BOD bottles 300 mL (several)
- BOD incubator at 20 C
- Burette, pipettes
- Measuring cylinder
- Air pump/aerator for dilution water
- Thermometer
Chemical Reagents
- Phosphate buffer solution
- Magnesium sulphate solution
- Calcium chloride solution
- Ferric chloride solution
- Seeded dilution water (distilled water + nutrients + settled sewage seed)
- Winkler reagents (manganous sulphate, alkali-iodide-azide, conc. H2SO4)
- Sodium thiosulphate (0.025 N)
- Starch indicator
Step-by-Step Practical Procedure
- Prepare dilution water: aerate distilled water, add 1 mL each of phosphate buffer, MgSO4, CaCl2 and FeCl3 per litre, then add settled sewage seed.
- Prepare at least three dilutions of the wastewater (e.g. 1%, 2%, 5%) in BOD bottles filled to the brim.
- Fill two BOD bottles with dilution water alone as blanks.
- Determine initial DO (D1) of one bottle of each dilution and one blank by Winkler titration.
- Incubate the remaining bottles in the dark at 20 C for 5 days.
- After incubation, determine final DO (D2) of each bottle.
- Select a dilution where D1 - D2 is between 2 and 7 mg/L and at least 1 mg/L residual DO remains.
- Calculate BOD5 = (D1 - D2) x dilution factor, correcting for blank depletion if needed.
Observations & Expected Results
DO falls during incubation; healthy dilution water blanks deplete less than 0.2 mg/L. Untreated domestic sewage: BOD5 100-300 mg/L. Treated sewage discharge standard (common): 30 mg/L.
Worked Stoichiometric Calculations
Problem: A 2% dilution of wastewater had initial DO 8.6 mg/L and final DO 4.1 mg/L after 5 days at 20 C. The blank showed negligible depletion. Calculate BOD5.
Working: Depletion = D1 - D2 = 8.6 - 4.1 = 4.5 mg/L. Dilution factor = 100/2 = 50. BOD5 = 4.5 x 50 = 225 mg/L, typical of untreated domestic sewage.
Safety Precautions & Hazard Control
- Keep incubation strictly at 20 +/- 1 C in complete darkness.
- Ensure no air bubbles are trapped when stoppering BOD bottles.
- Use a valid dilution showing 40-70% DO depletion.
- Do not use samples containing toxic substances without acclimatised seed.
Waste Disposal Protocol
Incubated samples contain sewage microorganisms; disinfect with bleach before disposal to the drain.
Viva Voce Oral Defense Questions & Answers
Q: Why is BOD measured over 5 days at 20 C?
A: The 5-day period at 20 C is the international convention; about 70% of ultimate carbonaceous BOD is exerted in this time, and 20 C approximates average river temperature.
Q: Why is the test done in the dark?
A: To prevent photosynthetic algae from producing oxygen, which would mask the oxygen consumed by bacteria.
Q: What is seeding and when is it needed?
A: Adding acclimatised microorganisms to dilution water; needed for sterile, chlorinated or industrial samples lacking a natural microbial population.