Chloride by Mercurimetry: Diphenylcarbazone Indicator
To determine chloride by titration with mercuric nitrate using diphenylcarbazone.
Theoretical Foundations
Hg2+ + 2Cl- -> HgCl2 (undissociated, K ~ 10^-13). The first excess Hg2+ forms a violet complex with diphenylcarbazone. Titration is at pH 2-3 (HNO3); it works in acid where Mohr fails. Mercury is highly toxic: microscale only.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipette
- 250 mL conical flask
- Fume cupboard
Chemical Reagents
- Chloride sample (unknown)
- Standard Hg(NO3)2 (0.01004 M)
- Diphenylcarbazone indicator
- Dilute HNO3
Step-by-Step Practical Procedure
- Pipette 25.00 mL sample into a flask (fume cupboard, gloves).
- Acidify to pH 2-3 with dilute HNO3.
- Add diphenylcarbazone indicator.
- Titrate with 0.01004 M Hg(NO3)2 to the first permanent violet.
- Calculate Cl- in mg/L (M = 35.45).
Observations & Expected Results
Colourless to violet endpoint. Typical titre about 12.40 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL sample needed 12.40 mL of 0.01004 M Hg(NO3)2. Find mg/L Cl.
Working: Moles Hg2+ = 0.01004 x 0.01240 = 0.00012450 mol. Moles Cl- = 2 x 0.00012450 = 0.00024899 mol in 25 mL = 0.0099597 M. Mass per litre = 0.0099597 x 35.45 = 353 mg/L.
Safety Precautions & Hazard Control
- Mercury compounds are highly toxic and bioaccumulative: gloves, fume cupboard, zero sink disposal.
- Work at microscale.
- Acidify with HNO3 only.
Waste Disposal Protocol
ALL mercury waste to the dedicated mercury container; never down the sink.
Viva Voce Oral Defense Questions & Answers
Q: Why does this work in acid when Mohr's does not?
A: The indicator is diphenylcarbazone (stable in acid) and HgCl2 formation needs no chromate equilibrium; Mohr's chromate converts to dichromate in acid.
Q: Why is mercurimetry rarely used today?
A: Mercury's extreme toxicity and disposal problems; argentometry or ion chromatography are preferred.