Phenol in Ethylenediamine: Tetrabutylammonium Hydroxide Titrant
To determine phenol by non-aqueous titration with tetrabutylammonium hydroxide (TBAH).
Theoretical Foundations
In the basic solvent ethylenediamine (or DMF), phenol behaves as a strong acid: C6H5OH + (C4H9)4N(+)OH(-) -> C6H5O(-)(C4H9)4N(+) + H2O (1:1). TBAH in toluene/methanol is the strong-base titrant; thymol blue (yellow to blue) marks the endpoint. Aqueous NaOH cannot titrate phenol sharply.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 250 mL conical flask
- Analytical balance
- Nitrogen line (optional)
Chemical Reagents
- Phenol sample
- TBAH (0.1000 M in toluene/methanol, standardised)
- Ethylenediamine or DMF
- Thymol blue indicator
Step-by-Step Practical Procedure
- Weigh accurately about 0.2353 g phenol.
- Dissolve in 50 mL ethylenediamine.
- Add thymol blue.
- Titrate with 0.1000 M TBAH to the blue endpoint.
- Standardise TBAH against benzoic acid the same day.
- Calculate % purity (M = 94.11).
Observations & Expected Results
Yellow to blue endpoint. Typical titre about 24.90 mL.
Worked Stoichiometric Calculations
Problem: 0.2353 g phenol needed 24.90 mL of 0.1000 M TBAH. Find % purity.
Working: Moles TBAH = 0.1000 x 0.02490 = 0.0024900 mol = moles phenol. Mass = 0.0024900 x 94.11 = 0.23433 g. Purity = 0.23433/0.2353 x 100 = 99.6%.
Safety Precautions & Hazard Control
- TBAH absorbs CO2 rapidly: protect with a soda-lime guard tube.
- Ethylenediamine/DMF: toxic vapours, fume cupboard, gloves.
- Phenol is corrosive: no skin contact.
Waste Disposal Protocol
Amine/organic waste to non-halogenated organic waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is TBAH used instead of NaOH?
A: NaOH is insoluble in these organic solvents and its water would level the basicity; TBAH is a soluble strong organic base.
Q: Why protect TBAH from CO2?
A: CO2 converts OH- to carbonate, weakening the titrant and causing a fading endpoint.