Chloride in Table Salt: Volhard Back Titration
To determine % Cl in table salt by Volhard's back-titration method.
Theoretical Foundations
Excess standard AgNO3 precipitates all Cl-: Ag+ + Cl- -> AgCl(s). Excess Ag+ is back-titrated with standard SCN-: Ag+ + SCN- -> AgSCN(s); the first excess SCN- gives red FeSCN(2+) with Fe3+ indicator. The method works in acid, unlike Mohr. AgCl is more soluble than AgSCN, so the precipitate is filtered (or coated) to avoid endpoint fading.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipettes
- 250 mL volumetric flask
- 250 mL conical flask
- Filter paper
- Analytical balance
Chemical Reagents
- Table salt
- Standard AgNO3 (0.1000 M)
- Standard KSCN (0.1000 M)
- Ferric ammonium sulfate indicator
- Dilute HNO3
Step-by-Step Practical Procedure
- Weigh about 0.5000 g salt; dissolve and make up to 250.0 mL.
- Pipette 25.00 mL into a flask; add 25.00 mL 0.1000 M AgNO3 and 5 mL dilute HNO3.
- Filter off AgCl (or add nitrobenzene to coat it).
- Add Fe3+ indicator to the filtrate.
- Back-titrate with 0.1000 M SCN- to the first permanent red.
- Calculate % Cl (M = 35.45).
Observations & Expected Results
White AgCl filtered off; back-titration to red FeSCN(2+). Typical back-titre about 16.45 mL.
Worked Stoichiometric Calculations
Problem: 0.5000 g salt to 250.0 mL; 25.00 mL aliquot + 25.00 mL of 0.1000 M AgNO3; back-titre 16.45 mL of 0.1000 M SCN-. Find % Cl.
Working: Total Ag+ = 0.1000 x 0.02500 = 0.0025000 mol. Excess = 0.1000 x 0.01645 = 0.0016450 mol. Ag+ for Cl- = 0.00085500 mol in aliquot. In 250 mL: 0.0085500 mol. Mass Cl = 0.0085500 x 35.45 = 0.30310 g. % = 0.30310/0.5000 x 100 = 60.6% (theory for NaCl 60.66%).
Safety Precautions & Hazard Control
- Acidify with HNO3; HCl would add chloride.
- Remove AgCl before back-titration or the endpoint fades as SCN- displaces Cl-.
- AgNO3: gloves, brown bottle.
Waste Disposal Protocol
Silver waste to silver recovery; acidic filtrate neutralised.
Viva Voce Oral Defense Questions & Answers
Q: Why is AgCl filtered off before the back titration?
A: AgCl is more soluble than AgSCN, so SCN- would slowly convert AgCl to AgSCN, consuming extra titrant and fading the endpoint.
Q: Why does Volhard work in acid while Mohr does not?
A: FeSCN(2+) is stable in acid and no chromate equilibrium is involved; Mohr's chromate indicator requires pH 7-10.