Copper by EDTA: PAN Indicator
To determine Cu2+ by EDTA titration with PAN indicator at pH 5.
Theoretical Foundations
Cu2+ + H2Y(2-) -> CuY(2-) + 2H+ (log K = 18.8). PAN (1-(2-pyridylazo)-2-naphthol) forms a red complex with Cu2+; the free indicator is yellow. Acetate buffer holds pH 5, where the endpoint is sharp and Fe3+/Al3+ interferences are reduced.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipette
- 250 mL conical flask
- Wash bottle
Chemical Reagents
- Cu(II) solution (unknown)
- Standardised EDTA (0.01004 M)
- Acetate buffer (pH 5)
- PAN indicator (0.1% in ethanol)
Step-by-Step Practical Procedure
- Pipette 25.00 mL Cu solution into a flask.
- Add acetate buffer (pH 5).
- Add 3 drops PAN (red).
- Warm to 40 C.
- Titrate with 0.01004 M EDTA to pure yellow.
- Calculate Cu in g/L (M = 63.55).
Observations & Expected Results
Red to yellow endpoint. Typical titre about 19.60 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL Cu solution needed 19.60 mL of 0.01004 M EDTA. Find g/L Cu.
Working: Moles EDTA = 0.01004 x 0.01960 = 0.00019678 mol = moles Cu2+ in 25 mL = 0.0078714 M. Mass per litre = 0.0078714 x 63.55 = 0.5002 g/L.
Safety Precautions & Hazard Control
- Keep pH at 5; PAN fails outside pH 4-6 for copper.
- Warm for a sharp endpoint.
- Fe3+ interferes; reduce it or mask with fluoride if present.
Waste Disposal Protocol
Copper/EDTA waste to heavy-metal aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: What is PAN?
A: 1-(2-pyridylazo)-2-naphthol, a metallochromic indicator: red with Cu2+, yellow when free.
Q: Compare with the iodometric copper method.
A: Iodometry is more selective for Cu (Zn does not interfere) but needs careful pH and nitrite removal; EDTA is faster but less selective.