CHEMVEN

Copper by EDTA: PAN Indicator

To determine Cu2+ by EDTA titration with PAN indicator at pH 5.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To determine Cu2+ by EDTA titration with PAN indicator at pH 5.

Theoretical Foundations

Cu2+ + H2Y(2-) -> CuY(2-) + 2H+ (log K = 18.8). PAN (1-(2-pyridylazo)-2-naphthol) forms a red complex with Cu2+; the free indicator is yellow. Acetate buffer holds pH 5, where the endpoint is sharp and Fe3+/Al3+ interferences are reduced.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 25 mL pipette
  • 250 mL conical flask
  • Wash bottle

Chemical Reagents

  • Cu(II) solution (unknown)
  • Standardised EDTA (0.01004 M)
  • Acetate buffer (pH 5)
  • PAN indicator (0.1% in ethanol)

Step-by-Step Practical Procedure

  1. Pipette 25.00 mL Cu solution into a flask.
  2. Add acetate buffer (pH 5).
  3. Add 3 drops PAN (red).
  4. Warm to 40 C.
  5. Titrate with 0.01004 M EDTA to pure yellow.
  6. Calculate Cu in g/L (M = 63.55).

Observations & Expected Results

Red to yellow endpoint. Typical titre about 19.60 mL.

Worked Stoichiometric Calculations

Problem: 25.00 mL Cu solution needed 19.60 mL of 0.01004 M EDTA. Find g/L Cu.

Working: Moles EDTA = 0.01004 x 0.01960 = 0.00019678 mol = moles Cu2+ in 25 mL = 0.0078714 M. Mass per litre = 0.0078714 x 63.55 = 0.5002 g/L.

Safety Precautions & Hazard Control

  • Keep pH at 5; PAN fails outside pH 4-6 for copper.
  • Warm for a sharp endpoint.
  • Fe3+ interferes; reduce it or mask with fluoride if present.

Waste Disposal Protocol

Copper/EDTA waste to heavy-metal aqueous waste.

Viva Voce Oral Defense Questions & Answers

Q: What is PAN?

A: 1-(2-pyridylazo)-2-naphthol, a metallochromic indicator: red with Cu2+, yellow when free.

Q: Compare with the iodometric copper method.

A: Iodometry is more selective for Cu (Zn does not interfere) but needs careful pH and nitrite removal; EDTA is faster but less selective.