Chlorate by Iron(II) Reduction: Back Titration with Dichromate
To determine chlorate in a sample by reduction with excess Fe(II) and back titration.
Theoretical Foundations
ClO3(-) + 6Fe2+ + 6H+ -> Cl- + 6Fe3+ + 3H2O (boiling, H2SO4). Excess Fe2+ is back-titrated: Cr2O7(2-) + 6Fe2+ + 14H+ -> 2Cr3+ + 6Fe3+ + 7H2O (diphenylamine sulfonate). Chlorates are strong oxidisers: keep away from organics.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL and 50 mL pipettes
- 250 mL conical flask
- Bunsen burner
Chemical Reagents
- Chlorate sample (e.g. weedkiller)
- FAS solution (0.1000 M, standardised)
- Standard K2Cr2O7 (0.01667 M)
- Dilute H2SO4
- Diphenylamine sulfonate indicator
- H3PO4
Step-by-Step Practical Procedure
- Pipette 25.00 mL chlorate solution into a flask.
- Add 50.00 mL 0.1000 M FAS and 20 mL dilute H2SO4.
- Boil gently 10 min; cool.
- Add H3PO4 and indicator.
- Back-titrate with 0.01667 M K2Cr2O7 to the violet endpoint.
- Calculate as g/L KClO3 (M = 122.55).
Observations & Expected Results
Orange Fe3+ solution; titration to intense violet. Typical back-titre about 12.40 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL sample + 50.00 mL of 0.1000 M FAS; back-titre 12.40 mL of 0.01667 M K2Cr2O7. Find g/L as KClO3.
Working: Total Fe2+ = 0.0050000 mol. Cr2O7(2-) = 0.01667 x 0.01240 = 0.00020671 mol; Fe2+ for dichromate = 6 x 0.00020671 = 0.00124026 mol. Fe2+ for chlorate = 0.00375974 mol. Moles ClO3(-) = /6 = 0.00062662 mol in 25 mL = 0.025065 M. Mass per litre = 0.025065 x 122.55 = 3.072 g/L.
Safety Precautions & Hazard Control
- Chlorates + organics can detonate: no filter paper, no grease near dry chlorate.
- Boil in H2SO4, never HCl (Cl2 would evolve).
- Cool before titrating.
Waste Disposal Protocol
Chromium waste to toxic-metals container; never mix chlorate waste with organics.
Viva Voce Oral Defense Questions & Answers
Q: Why is Fe(II) used in excess rather than direct titration?
A: Chlorate reduction is slow and needs boiling; excess Fe2+ guarantees completion, and the remainder is easily titrated.
Q: Why H2SO4 and not HCl for acidification?
A: Hot dichromate/Fe(III) oxidise Cl- to Cl2, consuming reagent and giving low Fe2+ (high chlorate) results.