CHEMVEN

Vitamin C Powder: Iodometric Assay of Ascorbic Acid

To determine the purity of ascorbic acid powder by direct iodine titration.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To determine the purity of ascorbic acid powder by direct iodine titration.

Theoretical Foundations

Ascorbic acid is oxidised to dehydroascorbic acid: C6H8O6 + I2 -> C6H6O6 + 2HI (1:1). The titration uses standard iodine with starch; the first excess I2 gives the blue endpoint. HPO3 stabilises ascorbic acid against air oxidation during preparation.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 100 mL volumetric flask
  • 250 mL conical flask
  • Analytical balance
  • Mortar

Chemical Reagents

  • Ascorbic acid powder (vitamin C)
  • Standard iodine solution (0.05000 M)
  • HPO3 (metaphosphoric acid) solution
  • Starch indicator
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh accurately about 0.2000 g ascorbic acid powder.
  2. Dissolve in HPO3 solution; make up to 100.0 mL.
  3. Pipette 25.00 mL into a flask.
  4. Titrate with 0.05000 M iodine to the first permanent blue with starch.
  5. Repeat and calculate % purity (M = 176.12).

Observations & Expected Results

Colourless to blue endpoint. Typical titre about 5.68 mL.

Worked Stoichiometric Calculations

Problem: 0.2000 g ascorbic acid powder dissolved to 100.0 mL; 25.00 mL aliquot needed 5.68 mL of 0.05000 M I2. Find % purity (M = 176.12).

Working: Moles I2 = 0.05000 x 0.00568 = 0.00028400 mol = moles ascorbic acid in aliquot. In 100 mL: 4 x 0.00028400 = 0.0011360 mol. Mass = 0.0011360 x 176.12 = 0.20007 g. Purity = 0.20007/0.2000 x 100 = 100.0%.

Safety Precautions & Hazard Control

  • Prepare solutions fresh; ascorbic acid oxidises in air.
  • HPO3 stabiliser prevents metal-catalysed oxidation.
  • Titrate promptly after dissolution.

Waste Disposal Protocol

Dilute iodide solutions may be flushed with water.

Viva Voce Oral Defense Questions & Answers

Q: Why is starch not added at the start here?

A: The titration is direct with iodine as titrant; starch is present from near the start in some protocols, but adding it near the end keeps the endpoint sharp and avoids starch-iodine clumps.

Q: Why does the method use HPO3?

A: Metaphosphoric acid chelates metal ions and provides acidity, both of which slow the air oxidation of ascorbic acid before titration.

← Back to Experiments Directory