Nitrite in Water: Excess-Permanganate Back Titration
To determine nitrite in a water sample by oxidation with excess permanganate and back titration.
Theoretical Foundations
Direct titration is poor because HNO2 is volatile. Instead, excess KMnO4 oxidises nitrite in acid: 2MnO4(-) + 5NO2(-) + 6H+ -> 2Mn2+ + 5NO3(-) + 3H2O. Unreacted MnO4(-) is back-titrated with standard oxalate. Nitrite is an environmental pollutant from fertilisers.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL and 50 mL pipettes
- 250 mL conical flask
- Thermometer
- Bunsen burner
Chemical Reagents
- Nitrite-containing water sample
- Standardised KMnO4 (0.02008 M)
- Standard sodium oxalate (0.05000 M)
- Dilute H2SO4 (2 M)
Step-by-Step Practical Procedure
- Pipette 25.00 mL sample into a flask.
- Add 50.00 mL 0.02008 M KMnO4 and 10 mL 2 M H2SO4.
- Warm to 40 C and let stand 10 min.
- Titrate the excess MnO4(-) with 0.05000 M oxalate at 60 C to colourless.
- Calculate nitrite as g/L NaNO2 (M = 69.00).
Observations & Expected Results
Purple fades partly during standing; back-titration goes pink to colourless. Typical back-titre about 12.40 mL.
Worked Stoichiometric Calculations
Problem: 25.00 mL sample + 50.00 mL of 0.02008 M KMnO4; back-titre 12.40 mL of 0.05000 M oxalate. Find g/L as NaNO2.
Working: Total MnO4(-) = 0.02008 x 0.05000 = 0.0010040 mol. Oxalate used = 0.05000 x 0.01240 = 0.00062000 mol; MnO4(-) equivalent = 0.00062000 x 2/5 = 0.00024800 mol. MnO4(-) for nitrite = 0.00075600 mol. Moles NO2(-) = 0.00075600 x 5/2 = 0.0018900 mol in 25 mL = 0.075600 M. Mass per litre = 0.075600 x 69.00 = 5.22 g/L.
Safety Precautions & Hazard Control
- Do not boil strongly; HNO2 is volatile.
- Allow full reaction time before back-titrating.
- Acidify adequately or MnO2 precipitates.
Waste Disposal Protocol
Acidic manganese/nitrate waste to heavy-metal aqueous waste.
Viva Voce Oral Defense Questions & Answers
Q: Why is back titration used for nitrite?
A: Nitrous acid is volatile and the direct reaction is slow; excess permanganate guarantees complete oxidation and the remainder is measured.
Q: Why must the solution stay strongly acidic?
A: In weak acid, permanganate reduces to brown MnO2 precipitate instead of Mn2+, ruining the stoichiometry.