CHEMVEN

Total Acidity of Wine: Titratable Acidity as Tartaric Acid

To determine the total (titratable) acidity of wine expressed as g/L tartaric acid.

Level: UniversitySafety: SafeTime: 45 min
Aim of Experiment: To determine the total (titratable) acidity of wine expressed as g/L tartaric acid.

Theoretical Foundations

Wine acids (tartaric, malic, citric) are titrated with NaOH to pH 8.2 (phenolphthalein): H2C4H4O6 + 2NaOH -> Na2C4H4O6 + 2H2O. Results are conventionally expressed as tartaric acid (M = 150.09, diprotic). CO2 is removed first since carbonic acid would inflate the result.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 10 mL pipette
  • 250 mL conical flask
  • pH meter (optional)
  • Vacuum flask (for degassing)

Chemical Reagents

  • Wine sample
  • Standardised NaOH (0.1000 M)
  • Phenolphthalein indicator
  • Distilled water

Step-by-Step Practical Procedure

  1. Degas the wine by gentle swirling under vacuum or standing 30 min.
  2. Pipette 10.00 mL into a conical flask; dilute to about 50 mL.
  3. Add phenolphthalein.
  4. Titrate with 0.1000 M NaOH to the first permanent pink (or pH 8.2).
  5. Repeat and express acidity as g/L tartaric acid.

Observations & Expected Results

Red wine darkens; endpoint seen as a persistent pink tinge. Typical titre about 6.80 mL.

Worked Stoichiometric Calculations

Problem: 10.00 mL wine needed 6.80 mL of 0.1000 M NaOH. Find total acidity as g/L tartaric acid (M = 150.09, diprotic).

Working: Moles NaOH = 0.1000 x 0.00680 = 0.000680 mol. Moles tartaric = 0.000680/2 = 0.000340 mol. Mass = 0.000340 x 150.09 = 0.05103 g per 10 mL = 5.10 g/L.

Safety Precautions & Hazard Control

  • Remove CO2 before titrating.
  • For red wines, dilute well or use a pH meter to see the endpoint.
  • Titrate to pH 8.2 exactly if a meter is available.

Waste Disposal Protocol

Neutralised wine solutions may go down the sink.

Viva Voce Oral Defense Questions & Answers

Q: Why is the result expressed 'as tartaric acid'?

A: Wine contains several acids; expressing total titratable protons as the dominant acid (tartaric) gives a single comparable number.

Q: How does volatile acidity differ?

A: Volatile acidity (mainly acetic acid) is measured by steam distillation; this titration gives total acidity including fixed acids.

← Back to Experiments Directory