Conductometric Titration: HCl with NaOH
To find the equivalence point of a strong acid-strong base titration from a conductance minimum.
Theoretical Foundations
Conductance depends on ion mobility: H+ (350 S cm2/eq) is far more mobile than Na+ (50). As NaOH is added, H+ is replaced by Na+: H+ + OH- -> H2O, so conductance falls linearly to a minimum at equivalence, then rises as excess OH- (198) and Na+ accumulate. The intersection of the two straight lines gives the endpoint without any indicator.
Required Apparatus & Chemicals
Laboratory Apparatus
- Conductivity meter with dip cell
- 50 mL burette
- 250 mL beaker
- Magnetic stirrer
- 25 mL pipette
Chemical Reagents
- HCl (approx 0.1 M)
- Standardised NaOH (approx 0.1 M)
- Distilled water
Step-by-Step Practical Procedure
- Pipette 25.00 mL HCl into a beaker; dilute to about 150 mL.
- Immerse the conductivity cell; record initial conductance.
- Add NaOH in 1.00 mL portions, stirring, recording conductance each time.
- Continue about 10 mL past the minimum.
- Plot conductance vs volume; extrapolate the two lines to their intersection.
- Calculate the acid molarity.
Observations & Expected Results
Conductance falls to a sharp V-shaped minimum at about 25.00 mL, then rises. No colour change is involved.
Worked Stoichiometric Calculations
Problem: 25.00 mL HCl; conductance minimum at 25.00 mL of 0.1000 M NaOH. Find M(HCl).
Working: Moles NaOH = 0.1000 x 0.02500 = 0.002500 mol = moles HCl. M(HCl) = 0.002500/0.02500 = 0.1000 mol/L.
Safety Precautions & Hazard Control
- Keep temperature constant; conductance rises about 2% per C.
- Rinse the cell with distilled water before use.
- Stir at constant speed; do not trap air bubbles on the electrodes.
Waste Disposal Protocol
Dilute neutral solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: Why does conductance fall before the equivalence point?
A: Highly mobile H+ ions are consumed and replaced by slower Na+ ions, so total conductance decreases.
Q: Why is the sample diluted before titration?
A: Dilution keeps conductance on scale and makes the relative changes larger and more linear.