Indicator Selection: Matching Indicator to Titration Type
To show experimentally that the correct indicator depends on the pH at equivalence for strong/weak acid-base pairs.
Theoretical Foundations
Equivalence pH: strong-strong about 7 (either indicator); weak acid-strong base above 7 (phenolphthalein only); strong acid-weak base below 7 (methyl orange only). Titrating 0.1 M CH3COOH with 0.1 M NaOH, the equivalence pH = 7 + 1/2(pKa + log C) = 8.73, inside phenolphthalein's 8.2-10.0 range but far above methyl orange's.
Required Apparatus & Chemicals
Laboratory Apparatus
- 50 mL burette
- 25 mL pipette
- 250 mL conical flasks
- pH meter (optional)
Chemical Reagents
- 0.1000 M HCl
- 0.1000 M NaOH
- 0.1000 M acetic acid
- 0.1000 M ammonia solution
- Methyl orange
- Phenolphthalein
Step-by-Step Practical Procedure
- Titrate HCl vs NaOH with methyl orange; note titre.
- Repeat the same titration with phenolphthalein; compare.
- Titrate acetic acid vs NaOH with phenolphthalein (titre A).
- Repeat with methyl orange; compare titre B with A.
- Titrate HCl vs ammonia with methyl orange and with phenolphthalein; compare.
- Tabulate which indicator gives the stoichiometric titre in each case.
Observations & Expected Results
Strong-strong: both indicators agree. Acetic acid-NaOH: phenolphthalein titre is larger and correct; methyl orange changes early (about 2 mL low). HCl-ammonia: reversed.
Worked Stoichiometric Calculations
Problem: 25.00 mL of 0.1000 M acetic acid titrated with 0.1000 M NaOH. Calculate the equivalence pH (pKa = 4.76).
Working: At equivalence [CH3COO-] = 0.05000 M. pH = 7 + 1/2(pKa + log C) = 7 + 0.5 x (4.76 + log 0.05) = 7 + 0.5 x (4.76 - 1.301) = 7 + 1.73 = 8.73. Phenolphthalein (8.2-10.0) is correct; methyl orange would signal about pH 4, far too early.
Safety Precautions & Hazard Control
- Use the minimum indicator (2 drops); large amounts shift the endpoint.
- Compare colours against a white tile.
- Standardise all four solutions first for quantitative comparison.
Waste Disposal Protocol
Dilute neutral solutions may be flushed with water.
Viva Voce Oral Defense Questions & Answers
Q: An indicator's range must bracket which pH?
A: The equivalence-point pH, and it must lie on the steep part of the titration curve so the colour change is sharp.
Q: Why do both indicators work for strong acid vs strong base?
A: The pH jumps from about 4 to 10 within a drop near 25.00 mL, covering both indicator ranges.