CHEMVEN

Sodium Bicarbonate in Baking Powder: Back Titration

To determine % w/w NaHCO3 in baking powder by back titration with standard HCl/NaOH.

Level: UniversitySafety: SafeTime: 60 min
Aim of Experiment: To determine % w/w NaHCO3 in baking powder by back titration with standard HCl/NaOH.

Theoretical Foundations

Baking powder contains NaHCO3 plus acid salts that react on wetting, so direct titration is unreliable. Excess standard HCl converts all bicarbonate: NaHCO3 + HCl -> NaCl + CO2 + H2O; the excess acid is back-titrated with standard NaOH (methyl orange). The difference gives the acid consumed by the sample.

Required Apparatus & Chemicals

Laboratory Apparatus

  • 50 mL burette
  • 50 mL pipette
  • 250 mL conical flask
  • Analytical balance
  • Bunsen burner

Chemical Reagents

  • Baking powder sample
  • Standardised HCl (approx 0.5 M)
  • Standardised NaOH (approx 0.5 M)
  • Methyl orange indicator
  • Distilled water

Step-by-Step Practical Procedure

  1. Weigh accurately about 2.000 g baking powder into a conical flask.
  2. Add 50.00 mL standard HCl; swirl and boil 2 min to expel CO2; cool.
  3. Add methyl orange.
  4. Back-titrate the excess HCl with standard NaOH to the yellow endpoint.
  5. Run a blank (no sample) the same way; calculate % NaHCO3.

Observations & Expected Results

Effervescence on adding acid; back-titration goes red to yellow. Typical back-titre about 32.40 mL of 0.5 M NaOH.

Worked Stoichiometric Calculations

Problem: 2.000 g sample + 50.00 mL of 0.5000 M HCl; back-titre 32.40 mL of 0.5000 M NaOH. Find % NaHCO3 (M = 84.01).

Working: Moles HCl added = 0.5000 x 0.05000 = 0.02500 mol. Excess = 0.5000 x 0.03240 = 0.01620 mol. Consumed = 0.00880 mol = moles NaHCO3. Mass = 0.00880 x 84.01 = 0.7393 g. % = 0.7393/2.000 x 100 = 37.0% w/w.

Safety Precautions & Hazard Control

  • Boil to expel CO2 or the back-titration endpoint drifts.
  • Cool before titrating; hot solutions damage the endpoint.
  • Weigh the powder quickly; it absorbs moisture.

Waste Disposal Protocol

Neutral salt solutions may be flushed with water.

Viva Voce Oral Defense Questions & Answers

Q: Why is back titration used instead of direct titration?

A: The sample's acid salts would partially neutralise the bicarbonate during a direct titration; excess strong acid drives the reaction to completion and the remainder is measured.

Q: Why must CO2 be boiled off before the back titration?

A: Dissolved CO2 (carbonic acid) would consume NaOH, making the excess acid appear smaller and the bicarbonate result falsely high.

← Back to Experiments Directory