Activation Energy: Temperature Dependence of a Dye-Fading Rate
To determine the activation energy of crystal violet fading from rate constants at two temperatures.
Theoretical Foundations
The Arrhenius equation k = A·e^(−Ea/RT) gives Ea = R·ln(k2/k1)/(1/T1 − 1/T2). Measuring the pseudo-first-order k for crystal violet + NaOH at 25 and 35 °C by A590 decay yields Ea, typically ~50 kJ mol⁻¹ for this reaction.
Required Apparatus & Chemicals
Laboratory Apparatus
- UV-Vis spectrophotometer
- Thermostatic baths (25, 35 °C)
- Pipettes
- Stopwatch
- Cuvettes
Chemical Reagents
- Crystal violet (2.0 × 10⁻⁵ M)
- Sodium hydroxide (0.10 M)
- Distilled water (blank and diluent)
Step-by-Step Practical Procedure
- Determine k at 25 °C from ln A590 versus t (as in anal-spec-061).
- Repeat the full kinetic run at 35 °C.
- Verify first-order behaviour at both temperatures.
- Apply the two-point Arrhenius equation.
- Calculate Ea in kJ mol⁻¹.
- Optionally add a third temperature for an Arrhenius plot.
Observations & Expected Results
Fading is markedly faster at 35 °C; ln k versus 1/T is linear; k roughly doubles per 10 °C.
Worked Stoichiometric Calculations
Problem: k = 0.0231 min⁻¹ at 25 °C (298 K) and 0.0462 min⁻¹ at 35 °C (308 K). Find Ea.
Working: Ea = 8.314 × ln(0.0462/0.0231)/(1/298 − 1/308) = 8.314 × 0.6931/(3.3557 × 10⁻³ − 3.2468 × 10⁻³) = 5.763/1.0896 × 10⁻⁴ = 5.29 × 10⁴ J mol⁻¹ = 52.9 kJ mol⁻¹.
Safety Precautions & Hazard Control
- Temperature control ±0.1 °C; k is exponentially sensitive.
- Use identical concentrations at both temperatures.
- Confirm the mechanism does not change with temperature.
- Start timing precisely at mixing.
Waste Disposal Protocol
Dilute dye/alkali waste to the aqueous drain after neutralization.
Viva Voce Oral Defense Questions & Answers
Q: What does Ea represent physically?
A: The minimum energy barrier reactant molecules must surmount; the Arrhenius exponential counts the fraction with enough energy.
Q: Why does k roughly double per 10 °C?
A: For Ea ≈ 50 kJ mol⁻¹ the Arrhenius factor gives about a twofold increase per 10 K near room temperature.
Q: Why use two temperatures only as an estimate?
A: Two points define a line but give no error check; three or more temperatures allow a proper Arrhenius fit.