CHEMVEN

Activation Energy: Temperature Dependence of a Dye-Fading Rate

To determine the activation energy of crystal violet fading from rate constants at two temperatures.

Level: UniversitySafety: SafeTime: 3 h
Aim of Experiment: To determine the activation energy of crystal violet fading from rate constants at two temperatures.

Theoretical Foundations

The Arrhenius equation k = A·e^(−Ea/RT) gives Ea = R·ln(k2/k1)/(1/T1 − 1/T2). Measuring the pseudo-first-order k for crystal violet + NaOH at 25 and 35 °C by A590 decay yields Ea, typically ~50 kJ mol⁻¹ for this reaction.

Required Apparatus & Chemicals

Laboratory Apparatus

  • UV-Vis spectrophotometer
  • Thermostatic baths (25, 35 °C)
  • Pipettes
  • Stopwatch
  • Cuvettes

Chemical Reagents

  • Crystal violet (2.0 × 10⁻⁵ M)
  • Sodium hydroxide (0.10 M)
  • Distilled water (blank and diluent)

Step-by-Step Practical Procedure

  1. Determine k at 25 °C from ln A590 versus t (as in anal-spec-061).
  2. Repeat the full kinetic run at 35 °C.
  3. Verify first-order behaviour at both temperatures.
  4. Apply the two-point Arrhenius equation.
  5. Calculate Ea in kJ mol⁻¹.
  6. Optionally add a third temperature for an Arrhenius plot.

Observations & Expected Results

Fading is markedly faster at 35 °C; ln k versus 1/T is linear; k roughly doubles per 10 °C.

Worked Stoichiometric Calculations

Problem: k = 0.0231 min⁻¹ at 25 °C (298 K) and 0.0462 min⁻¹ at 35 °C (308 K). Find Ea.

Working: Ea = 8.314 × ln(0.0462/0.0231)/(1/298 − 1/308) = 8.314 × 0.6931/(3.3557 × 10⁻³ − 3.2468 × 10⁻³) = 5.763/1.0896 × 10⁻⁴ = 5.29 × 10⁴ J mol⁻¹ = 52.9 kJ mol⁻¹.

Safety Precautions & Hazard Control

  • Temperature control ±0.1 °C; k is exponentially sensitive.
  • Use identical concentrations at both temperatures.
  • Confirm the mechanism does not change with temperature.
  • Start timing precisely at mixing.

Waste Disposal Protocol

Dilute dye/alkali waste to the aqueous drain after neutralization.

Viva Voce Oral Defense Questions & Answers

Q: What does Ea represent physically?

A: The minimum energy barrier reactant molecules must surmount; the Arrhenius exponential counts the fraction with enough energy.

Q: Why does k roughly double per 10 °C?

A: For Ea ≈ 50 kJ mol⁻¹ the Arrhenius factor gives about a twofold increase per 10 K near room temperature.

Q: Why use two temperatures only as an estimate?

A: Two points define a line but give no error check; three or more temperatures allow a proper Arrhenius fit.

← Back to Experiments Directory