First-Order Kinetics: Catalyzed Decomposition of H2O2 at 240 nm
To verify first-order kinetics for iodide-catalyzed H2O2 decomposition by UV at 240 nm.
Theoretical Foundations
H2O2 absorbs at 240 nm while water does not, so A240 tracks [H2O2] directly. For first-order decay, ln(A_t) versus t is linear with slope −k. The half-life is concentration-independent, confirming first order.
Required Apparatus & Chemicals
Laboratory Apparatus
- UV spectrophotometer
- Quartz cuvettes
- Pipettes
- Stopwatch
Chemical Reagents
- Hydrogen peroxide (0.10 M)
- Potassium iodide catalyst (0.01 M)
- Distilled water
Step-by-Step Practical Procedure
- Mix H2O2 with a trace of KI catalyst; start timing.
- Record A240 every 2 min for 30 min.
- Plot ln(A) versus time.
- Determine k from the slope.
- Calculate t½ and check it is constant between successive half-lives.
- Repeat without catalyst to show catalysis.
Observations & Expected Results
A240 decays exponentially; ln plot linear; typical k ≈ 0.035 min⁻¹ with catalyst.
Worked Stoichiometric Calculations
Problem: A240 falls from 0.800 to 0.400 in 20.0 min. Assuming first order, find k.
Working: One half-life = 20.0 min (0.800 → 0.400). k = 0.693/t½ = 0.693/20.0 = 0.0347 min⁻¹.
Safety Precautions & Hazard Control
- H2O2 is corrosive; wear gloves and goggles.
- Use quartz cuvettes for 240 nm.
- Keep catalyst concentration identical between runs.
- Avoid transition-metal contamination which catalyzes erratically.
Waste Disposal Protocol
Dilute peroxide/iodide waste to the aqueous drain.
Viva Voce Oral Defense Questions & Answers
Q: How does constant half-life prove first order?
A: Only first-order reactions have t½ = 0.693/k independent of initial concentration.
Q: What is the catalyst's role?
A: I⁻ provides a lower-energy pathway (via HIO intermediate) without being consumed.
Q: Why quartz cuvettes?
A: Glass absorbs at 240 nm; quartz is transparent in the UV.