Iodine Clock Kinetics: Persulfate-Iodide Reaction at 350 nm
To measure the initial rate of the persulfate-iodide reaction from I3⁻ growth at 350 nm.
Theoretical Foundations
S2O8²⁻ + 2I⁻ → 2SO4²⁻ + I2; iodine complexes as I3⁻ (λmax 350 nm, ε ≈ 2.6 × 10⁴). The initial slope dA/dt divided by ε·l gives the reaction rate in mol L⁻¹ min⁻¹. Varying reactant concentrations yields the rate law.
Required Apparatus & Chemicals
Laboratory Apparatus
- UV-Vis spectrophotometer
- Pipettes
- Stopwatch
- Cuvettes
- Thermostatic bath
Chemical Reagents
- Potassium persulfate (0.10 M)
- Potassium iodide (0.20 M)
- Sodium thiosulfate (for check)
Step-by-Step Practical Procedure
- Thermostate all solutions at 25 °C.
- Mix persulfate and iodide; start timing.
- Record A350 every 30 s for 10 min.
- Plot A versus t; take the initial slope dA/dt.
- Convert to rate using ε = 2.6 × 10⁴.
- Repeat with halved [I⁻] to find the order in iodide.
Observations & Expected Results
A350 rises linearly at first; typical initial slope ≈ 0.012 A min⁻¹.
Worked Stoichiometric Calculations
Problem: Initial dA/dt = 0.012 min⁻¹ at 350 nm (ε = 2.60 × 10⁴, l = 1 cm). Find the initial rate in mol L⁻¹ min⁻¹.
Working: Rate = (dA/dt)/(ε·l) = 0.012/2.60 × 10⁴ = 4.62 × 10⁻⁷ mol L⁻¹ min⁻¹.
Safety Precautions & Hazard Control
- Use the initial linear portion only.
- Thermostate; the reaction is temperature-sensitive.
- Protect from light; photochemical side reactions occur.
- Prepare persulfate fresh; it decomposes slowly.
Waste Disposal Protocol
Iodide/iodine waste to the aqueous halogen waste bottle.
Viva Voce Oral Defense Questions & Answers
Q: Why use the initial rate?
A: Reactant concentrations are then known (equal to initial) and reverse/product effects are negligible.
Q: Why does I3⁻ absorb at 350 nm while I⁻ does not?
A: I3⁻ has low-energy charge-transfer transitions absent in simple I⁻, giving the strong 350 nm band.
Q: How is the order in persulfate found?
A: Vary [S2O8²⁻] at fixed [I⁻] and compare initial rates; rate ∝ [S2O8²⁻]^m.