CHEMVEN

Zinc Determination: Dithizone Extraction at 538 nm

To determine zinc by extraction of the red zinc dithizonate into chloroform at 538 nm.

Level: UniversitySafety: Needs supervisionTime: 90 min
Aim of Experiment: To determine zinc by extraction of the red zinc dithizonate into chloroform at 538 nm.

Theoretical Foundations

Dithizone forms a red 1:2 complex Zn(HDz)2 extractable into chloroform (λmax 538 nm, ε ≈ 2.9 × 10⁴). At pH 4-5 with thiosulfate masking heavy metals, zinc extracts selectively. Excess green dithizone is scrubbed from the extract with dilute ammonia, leaving the red zinc complex.

Required Apparatus & Chemicals

Laboratory Apparatus

  • UV-Vis spectrophotometer
  • Separating funnels
  • Volumetric flasks 50 mL
  • Pipettes
  • Cuvettes

Chemical Reagents

  • Zn standard (1 mg L⁻¹)
  • Dithizone (0.01% in chloroform)
  • Acetate buffer (pH 4.5)
  • Sodium thiosulfate
  • Dilute ammonia
  • Water sample

Step-by-Step Practical Procedure

  1. Place 0-10 mL Zn standard in funnels (0-0.2 mg L⁻¹ after dilution).
  2. Add buffer, thiosulfate and 10 mL dithizone solution.
  3. Shake 2 min; separate the chloroform layer.
  4. Scrub the extract with dilute ammonia to remove excess dithizone.
  5. Dilute to 50 mL; treat the sample identically.
  6. Zero at 538 nm with CHCl3; read and calculate zinc.

Observations & Expected Results

Red extract after ammonia scrub; green excess dithizone removed; A538 linear with Zn.

Worked Stoichiometric Calculations

Problem: An extract gives A = 0.430 at 538 nm (ε = 2.90 × 10⁴, l = 1 cm). Find Zn in the measured extract in mg L⁻¹.

Working: c = 0.430/2.90 × 10⁴ = 1.48 × 10⁻⁵ mol L⁻¹ = 1.48 × 10⁻⁵ × 65.38 × 1000 = 0.970 mg L⁻¹ Zn.

Safety Precautions & Hazard Control

  • Dithizone is light-sensitive; prepare fresh and store dark.
  • Scrub excess dithizone; it absorbs near the analytical wavelength.
  • Mask Cu, Pb, Cd with thiosulfate at pH 4.5.
  • Use chloroform in a fume cupboard.

Waste Disposal Protocol

Chloroform extracts to halogenated waste; aqueous layer to heavy-metal waste.

Viva Voce Oral Defense Questions & Answers

Q: Why scrub with dilute ammonia?

A: Excess green dithizone absorbs near 538 nm; ammonia back-extracts it into water while the red zinc complex stays in chloroform.

Q: Why pH 4.5?

A: Zinc dithizonate extracts quantitatively at pH 4-5 while many interfering metals are masked by thiosulfate in this range.

Q: Why must dithizone be fresh?

A: It oxidises in light and air to species that do not chelate, lowering extraction efficiency.

← Back to Experiments Directory